![TEXTCARE Main Sensor Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/textcare/main-sensor/main-sensor_user-manual_1097686021.webp)
ADVANCED SETUP
PAGE 20
Light
if a light level (above 2) is detected between start and stop times, an alarm text will
be sent.
NOLight
if light is not detected between start and stop times, an alarm text will be at the
end time.
Sound
if a sound level above 2 is detected between start and stop times, an alarm text
will be sent.
NOSound
if sound is not detected between start and stop times, an alarm text will be
sent the end time.
TEMP>
if the temperature goes above the specified level between the start and stop
time, an alarm text will be sent
TEMP<
if the temperature goes below the specified level between the start and stop
times, an alarm text will be sent.
4) Start time window e.g. 08:00 The time you want the alarm monitoring to start 08:00
(24hr clock)
5) End time window e.g. 10:30 The time you want the alarm monitoring to finish 10:30
(24hr clock)
6) Alarm to e.g. 1 to 9 or all The phone or phones the alarm text will be sent to.
EXAMPLE 1
ALARM1= kitchen ,NoMove, 08:00 , 13:30,1
Alarm condition ‘1’ will be set to Kitchen sensor, if no movement is detected between
8am and 1:30pm a text will be sent to phone ‘1’
EXAMPLE 2
ALARM2=Bedroom ,temp<15, 22:00 , 07:30,A
Alarm condition ‘2’ will be set to Bedroom sensor, if the temperature drops below 15’C
between 10pm and 7:30am a text will be sent to all phones registered.
EXAMPLE3
ALARM3=Hallway ,light, 01:00 , 05:30,2
Alarm condition ‘3’ will be set to the Hallway sensor, if the light is detected between
1am and 5:30am a text will be sent to phones 3.
TIME1#
TIME2=19:30,2