Common faults, root cause for these and suggested actions are provided in TABLE 2 below:
Fault
Possible causes
Suggested actions
Pump does
not discharge
water
Faulty foot valve / strainer
Check and replace
Pump not primed
Prime the pump
Air leakage on the suction side
Check and correct for leakages
Suction lift too high
Reduce the static suction lift
Foot valve not sufficiently
submerged
Lower the foot valve and ensure that the foot
valve is submerged at least 1 metre below the free
surface of water
Motor coil burnt
Rewind the motor
Low-voltage operation
Operate in the recommended voltage range
Less discharge
from pump
Low voltage operation
Operate in the recommended voltage range
Wrong direction of rotation
Repair in the nearest authorized service centre
Static suction lift high
Position the pump within recommended suction lift
Total head higher than specified
Ensure delivery head within specified value
Leaky pipes
Check the piping system and rectify the faults
Smaller pipe size used when
compared to nameplate
recommendations
Use recommended size of pipes
11. Basic troubleshooting
Warning
To prevent serious accidents, disconnect the power supply before
inspecting the pump.