Caution
The supply voltage should be within the specified voltage range.
Water temperature for operation of the pump should not exceed 33
0
C
Failure to observe the precautions given above could cause the pump to
malfunction and may lead to current leakage or electrical shock
Warning
If you find any abnormalities like vibration, noise, smell, etc. from the pump
during trial operation, switch OFF the pump and contact the dealer where this
pump was purchased
10. Installation procedure
Please follow the below procedure to assemble the Single Phase Self-Priming Monoblock:
The following steps are executed prior to installation
Installation:
Measure the Insulation Resistance using a Megger of 500 VDC
Ensure contact points are clean
Connect the measuring cable to the ground conductor
Connect the other measuring cable to phase terminal
Ensure that the insulation resistance, as shown on the Megger, is a minimum of 20MΩ
Prepare a level concrete foundation for mounting the Single Phase Self-Priming Monoblock and
tighten the motor base using the foundation bolts as shown in Fig. 6 below:
Fig. 6 Self - priming monoblock on a concrete
foundation - installation
CONCRETE
BASE
FOUNDATION
STUD & NUT