Texmate, Inc. Tel. (760) 598-9899 • www.texmate.com
Page 6
Apr-21-2016 DI_602A 320 DS (NZ313)_April 2016
Front Panel Controls and Indicators
Program Button
While programming, pressing the
P
button saves the current pro-
gramming settings and moves to the next programming step.
You can move through the programming codes using the program
button. The codes you pass are not affected, unless you stop and
make changes using the or buttons.
Pressing the
P
and button at the same time initiates the
main programming mode
. To save a new configuration setting
and return to the operational display, press the
P
button once
and then press the
P
and button at the same time.
Pressing the
P
and button at the same time initiates the
setpoint programming mode
. To save a new configuration
setting and return to the operational display, press the
P
button
once and then press the
P
and
button at the same time.
See Display with Faceplate and Bezel diagram.
Up Button
When setting a displayed parameter during programming, press
the
button to increase the value of the displayed parameter.
When in the operational display, pressing the button initiates
a viewing mode that allows you to view the readings on
chan-
nels 1 and 3, setpoints 1, 3, and 5, peak, and total 1
. Once
into the viewing routine, pressing the button moves through each
displayed parameter.
See Display with Faceplate and Bezel diagram.
Down Button
When setting a displayed parameter during programming, press
the
button to decrease the value of the displayed parameter.
When in the operational display, pressing the button initiates
a viewing mode that allows you to view the readings on
chan-
nels 2 and 4, setpoints 2, 4, and 6, valley, and total 2
. Once
into the viewing routine, pressing the button moves through each
displayed parameter.
Function Buttons
Function buttons
F1
and
F2
activate pre-programmed macros on
demand. each macro is written to activate from a specific function
button. When the function button is pressed, the macro carries out
its designated tasks.
See Display with Faceplate and Bezel diagram.
Annunciator LEDs
The annunciator LEDs can be programmed to indicate the alarm
status.
Setpoint 1 can be configured to indicate the
rising
signal trend.
Setpoint 2 can be configured to indicate the
falling
signal trend.
They are labeled from left to right: SP1, SP2, SP3, SP4, SP5, SP6.
See Display with Faceplate and Bezel diagram.
Dual LED Display
The DI-602A has two 6-digit, 14-segment, 0.39” (10 mm) stan-
dard red, green or red/green LED displays. The LED displays are
used to display two independent input signals, or a combination
of processed signals such as rate and total.
Top Display
The top display is known as the primary display during pro-
gramming and displays the three digit code settings when in a
programming mode.
Bottom Display
The bottom display is known as the secondary display during
programming and displays the programming code number or
sub-menu name.
Controls and Indicators
Controls and Indicators
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Display Text Editing with 14 Segment Full
Alphanumeric Display Characters
Display text, such as setpoints, can be easily edited to suit your
application, by connecting the meter to a PC running the free
downloadable Configuration Utility program.
For Example:
Instead of [SP_1]
could be used for
TANK LOW
Instead of [SP_2]
could be used for
BRAKE OFF
OR
SP1
SP3
SP4
SP5
SP6
SP2
F1
F2
P
SP1
SP3
SP4
SP5
SP6
SP2
F1
F2
P
Scrolling Display Text Messaging
Scrolling display text messaging can be configured to run with
a simple macro.
SP1
SP3
SP4
SP5
SP6
SP2
F1
P
F2
Display Text Characters
The following text characters are used with the 14-segment full
alphanumeric display.
14-SEGMENT DISPLAY CHARACTERS
UP
Button
DOWN
Button
PROGRAM
Button
LED
Annunciators
for Setpoints
1-6
F2
Button
F1
Button
SP1
SP3
SP4
SP5
SP6
SP2
Prog
F2
F1
Optional Membrane Touch Pad Faceplate
UP
Button
DOWN
Button
PROGRAM
Button
LED
Annunciators
for Setpoints
1-6
F2
Button
F1
Button
Seven Segment
LED Displays
Display PCB without Faceplate and Bezel
Display with Faceplate and Bezel