background image

Texmate, Inc. Tel. (760) 598-9899  •  www.texmate.com

FL-B101Q-HZ_manual (d0059)

Page 1

•   AC Line Frequency Range 45-200Hz @ 80-300VAC
•   A red or optional green, Tri-color 101 segment bargraph.
•  Two 9 Amp Form C, and two 4 Amp Form A relays available
•  Optional  isolated  16  bit  analog  output.  User  or  factory 

scalable to 4 to 20 mA, 0 to 20 mA or 0 to 10 V across any 

desired span from ± one bar to the full scale range

•  Provision  to  connect  an  external  programming  lockout 

switch. 

•  Optional NEMA-4 front cover.
•  Four programmable setpoints.
•  Relays activation can be selected to occur above (HI) or 

below (LO) each setpoint.

•  Optional  6  inch  adaptor  to  replace  switch  board  analog 

meters. 

•  UL Listed

Input Specs

:

 ..............

Differential with Frequency to Voltage con-

verter.  Inputs  resistively  isolated  to  1400V 

from  the  internal  ground  of  meter  by 

1.94MΩ, so that phase to phase measure-

ments up to 300V AC can be safely made

 

Full Scale Ranges

:

......Factory installed range of 45Hz to 200Hz.

A/D Converter

:

 ..........14 bit single slope

Accuracy

:

 ..................±(0.05% of r 1segment)

Temp. Coeff.: .............100 ppm/°C (Typical)

Warm up time

:

 ...........2 minutes

Conversion Rate

:

 ......10 conversions per second (Typical)

Bargraph Display

:

 .....101 segment 4” vertical (std)

 

horizontal (optn), red (std), green (optn), 

Positive Overrange

:

 ..Bargraph display flashes

Negative Overrange

First segment of bargraph display flashes

Relay Output

:

 ............Two  4  Amp  Form  A  relays  and  Two 

 

9 Amp Form C relays 

Analog Output

:

 .........Isolated 16 bit user scalable mA or V

  OIC (mA out) ...........4-20 mA @ 0 to 500Ω max loop resistance

  OIV (volts out) .......... 0-10 V DC @ 500 Ω or higher resistance

Power Supply

:

 ...........AC/DC Auto sensing wide range supply

 

PS1 (std) ................85-265 VAC, 50-400 Hz / 95-300 VDC @ 4.2W

  PS2 .........................15-48 VAC,50-400 Hz / 10-72 VDC @ 4.2W

Operating Temp.: ......0 to 50°C

Storage Temp

:

 ...........–20°C to 70°C

Relative Humidity

:

 ....95% (non condensing)

Case Dimensions

:

 ....3/32 DIN, Bezel: 36x144 mm(1.42”x5.69”)

 

Depth  behind  bezel:  (4.64")  117.5  mm

 

Plus 10 mm (0.39”) for Right-angled con-

nector, or plus 18.3 mm (0.72”) for Straight-

thru connector, or plus 26.5 mm (1.05”) for 

Push-On connector.

Weight

:

 .......................9.5 oz., 12 oz when packed

General Features

Input Module Compatibility

Specifications

Index

LEOPARD FAMILY

 

LEOPARD 

 LEOPARD FAMILY: 

 

More  than  50  different 

Plug-in  I-Series  Input  Signal  Conditioners  are 

approved for Leopard Family meters. 

See www.texmate.com for an up to date listing.

Analog Output Scaling and Calibration . . . . . . . . . . . 9

Case Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Component Layout  . . . . . . . . . . . . . . . . . . . . . . . . .

11

Connector Pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Connectors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . 2

Custom Face Plates and Scale. . . . . . . . . . . . . . . . 13

Glossary of Programming Symbols and Modes of 

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

General Features. . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Input Module Compatibility  . . . . . . . . . . . . . . . . . . . . . .

1

Input Module Component Glossary. . . . . . . . . . . . . . .

11

Installation  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

One Point Quickset Rescaling and Calibration 

Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6

Ordering Information . . . . . . . . . . . . . . . . . . . . . . . . 14

Opening the Case to Access Mode Select Headers . . .4

Overview of Display Modes, Scaling Capabilities and 

Operation Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

Pin Descriptions. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Setpoint Adjust. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

Setting the Colors  . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1

Standard Display Mode Calibration Procedure. . . . . 6

Two Point Quickset Scaling and Calibration . . . . . . . 5

FL-B101Q-HZ

Leopard Bargraph Meter

AC Line Frequency

101 Segment in a 9/64 DIN CASE

High Accuracy Programmable AC Line Frequency Bargraph Meter and Transmitter. 

Range 45-200Hz@80-300VAC, Optional 4-20mA or 0-10VDC Output.

Suitable for Power Generators and Switchboard Analog Meter Replacement.

Содержание FL-B101Q-HZ

Страница 1: ...upply AC DC Auto sensing wide range supply PS1 std 85 265 VAC 50 400 Hz 95 300 VDC 4 2W PS2 15 48 VAC 50 400 Hz 10 72 VDC 4 2W Operating Temp 0 to 50 C Storage Temp 20 C to 70 C Relative Humidity 95 n...

Страница 2: ...there are no menu or sub menus to navigate the programming and setup is quick and Span Buttons Span Zero Buttons Zero Set Point Button SP1 SP2 SP3 SP4 Front Panel Buttons Zero Button The Zero Button s...

Страница 3: ...d Mode 3 Hysteresis Band between SP1 SP2 This mode enables the Hysteresis function In order for Hysteresis to function SP2 must be set to a value greater than SP1 and SP2 should be selected as High h...

Страница 4: ...and carefully lever the plastic catch up and tilt the Display Board assembly forward Then repeat this action with the bottom catches Step 5 Remove the entire Display Board assembly by sliding it out o...

Страница 5: ...SPAN but ton is pressed the input signal being applied must be more than 5 higher or lower than the previously memorized value of the input signal that was being applied when the other button was last...

Страница 6: ...20mA If now the scaling has to be changed to read zero to full scale for an input of 0 to 20mA only the low 4 mA end needs to be recalibrated The high 20 mA end of the scaling is left untouched and so...

Страница 7: ...d SP4 activate when input is lower than set point SP1 and SP3 activate when input is equal to or higher than set point SP2 activate when input is lower than set point SP1 SP3 and SP4 activate when inp...

Страница 8: ...color overrides the SP1 color STEP A ENTER COLOR SET MODE Hold down ALL four setpoint buttons SP1 SP2 SP3 and SP4 and apply power to the meter The meter will light up in the Color Set Mode Release all...

Страница 9: ...utton adjust the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of ch...

Страница 10: ...0 to 20 mA 4 to 20 mA or V 0 to 10 V output is header selectable Pin 19 Programming LOCK By connecting the LOCK pin to the COMMON pin the meter s programmed parameters can be viewed but not changed P...

Страница 11: ...omponent Glossary SPAN Turn Clockwise to Increase Reading To the Right Rear SPAN Potentiometer Pot If provided the 15 turn SPAN pot is always on the right side as viewed from the rear of the meter Typ...

Страница 12: ...I series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an existing 6 edgewise pointer meter cut out 100 0 25 50 75 100 0 25 50 75 SP1 SP2 SP3...

Страница 13: ...6 Metal Surround Case includes screw mounting clips 25 OP MTLCLIP Screw Mounting Clips 2 pc to screw tighten slide brackets 8 OP N4 144X36 144x36mm clear lockable front cover NEMA 4X splash proof 30 O...

Отзывы: