User Guide
6
INS046-8
To Program the Zones which CHIME
To program the zones which will chime,
enter your 4 digit code
!!!!
. The Unset light will flash.
Press
+
. The display will
illuminate the zones that will Chime.
Press the appropriate numbered
button(s)
!
…
of the individual zone(s) to be included or excluded.
Press
)
to turn Chime on (the system will sound the chime tone)
or press
*
to turn Chime off (the system will sound an error tone).
To Turn CHIME On or Off
To turn Chime on or off
press
+
. The system will sound the chime tone
when Chime is turned on and an error tone when Chime is turned off.
If no zones have been programmed to Chime then turning Chime
on and off will have no effect.
To Test the Sounders and Strobe
The control panel has a test facility to check the operation of the internal
sounder, the external sounder and strobe.
Enter your 4 digit code
!!!!
. The Unset light will flash.
Press
)
. All the zone lights
will illuminate.
Enter
,-
. All the zone lights will turn off. The system
outputs may be tested as follows:
Key
System Output
&
Internal sounder at high level (alarm level)
%
Internal sounder at low level (entry/exit level)
$
Strobe
#
External sounder (bell)
,
Turns off all of the above
The zone light corresponding to the number pressed will illuminate.
Press
*
. All the zone lights will illuminate.
Press
*
again.
The system will return to unset and all the zone lights will turn off.
To Display Log Events
The control panel is capable of recalling the last 7 alarm activations. The
zone light of the zone which first caused the alarm activation will flash,
and the zone lights of all subsequently opened zones (if any) will
illuminate.
!
!