INS181-4 8/9

LED RKP 4, 8 & 16

Allow system to operate for 30 seconds

1.

Enter installer/engineer code – would display confirm devices

2.

Press Arm Key – Enter confirm devices menu (Top line of LED’s will illuminate)

3.

Press Arm Key – Accept Detected network devices (All zone LED’s will un-illuminate)

4.

Press Arm Key – Confirm detected devices, exit installer menu and returns to day mode operation

5.

RKP+8

Allow system to operate for 30 seconds

1.

Enter installer/engineer code – would display confirm devices

2.

Press Yes Key – Enter confirm devices menu (All zone LED’s will illuminate)

3.

Press Yes Key – Accept Detected network devices (All zone LED’s will un-illuminate)

4.

Press Yes Key – Confirm detected devices, exit installer menu and returns to day mode operation

5.

RKP+16

Allow system to operate for 30 seconds

1.

Enter installer/engineer code – would display confirm devices

2.

Press Yes Key – Enter confirm devices menu (All zone LED’s will illuminate)

3.

Press Yes Key – Accept Detected network devices (All zone LED’s will un-illuminate)

4.

Press Yes Key – Confirm detected devices, exit installer menu and returns to day mode operation

5.

Any premier International panels containing a software version prior to V14.02 that is flashed with version V14.02 or later, The Confirm Devices strings

are not loaded in the panel’s memory so any reference to them results in black squares being shown.

Reload English Text Strings

This can be achieved by entering the Installers code and then pressing the keypad’s “Menu” key this provides a short cut to the language
setting menu. Once the selected language is transferred from flash to memory the Confirm Devices strings will be displayed.

Updated versions of the panel firmware can be found on our FTP server, or by contacting Technical Support.

1.7 Technical Specifications

Operating Voltage: 9 – 13.7VDC
Current Consumption: Nominal: 35mA; When fully back lit: 85mA
Zone Indicators: 16 on the RKP16/Plus; 8 on the RKP8/Plus 4 on RKP4
Status Indicators: RKP Plus Alarm: Red; Service: Yellow; Fire: Red; Bypass/Omit: Red; Instant:
Red; Stay/Part: Red; Ready: Green; Armed: Red
Status Indicators: RKP4/8/16 Alarm: Red; Trouble: Yellow; Armed: Red; Ready: Green
Data Bus: 4-wire up to 250m Star, Daisy-Chain or any combination
Operating Temperature: -10

°

C to +45

°

C

Storage Temperature: -20

°

C to +60

°

C

Maximum Humidity: 95% non-condensing

Содержание Premier RKP16

Страница 1: ...Installation Manual PREMIER RKP4 8 16 RKP8PLUS 16PLUS INS181 4 ...

Страница 2: ...nstallation 3 1 1 Mounting RKP8 16 Plus 3 1 2 Mounting RKP4 8 16 3 1 3 Selecting an Address 5 1 4 Cable Entry RKP4 8 16 5 1 5 Wiring 7 1 6 Programming Confirm Devices 7 1 7 Technical Specifications 8 1 8 Standards 9 1 9 Warranty 9 ...

Страница 3: ...e of the unit Gently push the screwdriver to ease the retaining clips upward DO NOT LEVER OR TWIST Excessive force is NOT required The front flap and front cover can now be removed 1 2 Mounting RKP4 8 16 Open the keypad by carefully inserting a small flat blade screwdriver into both screw covers The PCB assembly is hinged for easy access Alternatively the PCB assembly can be unclipped and complete...

Страница 4: ...INS181 4 4 9 ...

Страница 5: ...ess Each keypad MUST be given a different address using the DIP switch on the left hand side of the PCB as follows N NEVER set two RKPs to the same address Keypads are factory set to Address 1 all switches off 1 4 Cable Entry RKP4 8 16 ...

Страница 6: ...INS181 4 6 9 Cable entry MUST use either the top left hand hole or the cable channel NEVER run cables behind the PCB ...

Страница 7: ... on 0V will be more beneficial than doubling up on 12V and 0V Keypad Zones The Premier RKP8 16 Plus has two fully programmable zone inputs Z1 COM Z2 For information on wiring configuration options please refer to the Premier 412 816 Installation Manual In order to use the keypad zones you must first enable the zones using Menu 43 Option 1 refer to the Premier 412 816 Installation Manual When a keyp...

Страница 8: ...es exit installer menu and returns to day mode operation 5 N Any premier International panels containing a software version prior to V14 02 that is flashed with version V14 02 or later The Confirm Devices strings are not loaded in the panel s memory so any reference to them results in black squares being shown Reload English Text Strings This can be achieved by entering the Installers code and the...

Страница 9: ...vice does not contain lead mercury cadmium hexavalent chromium polybrominated biphenyls PBB or polybrominated depheny ethers PBDE in more than the percentage specified by EU directive 2002 95 EC except exemptions stated in EU directive 2002 95 EC annex This product Type B Moveable device And is suitable for use in systems designed to comply with EN 50131 1 EN50131 3 at Grade 2 and Environmental Cla...

Отзывы: