INS181-4 7/9
1.5 Wiring
It is strongly recommended that the system is completely powered down (mains and battery) before wiring a keypad. Connect the keypad to the control panel using
4-core cable as follows:
Up to six keypads may be connected in parallel (‘star’) or series (‘daisy‑chain’) or any combination.
N
When using long cable runs or connecting keypads in series (‘daisy‑chain’) ensure that the voltage at the keypad is no less than 10.0V. When using 6-core or 8-core
cable always use the spare cores to ‘double-up’ on 0V. This will allow longer cable runs particularly when connecting keypads in series (‘daisy‑chain’). As a rule ‘trebling‑up’ on 0V
will be more beneficial than ‘doubling-up’ on 12V and 0V.
Keypad Zones
The Premier RKP8/16 Plus has two fully programmable zone inputs (Z1 COM Z2). For information on wiring configuration options please refer to the Premier
412/816 Installation Manual.
In order to use the keypad zones, you must first enable the zones using Menu 43 Option 1 (refer to the Premier 412/816 Installation Manual). When a keypad has its
zones enabled they are mapped onto the system as shown:
1.6 Programming/Confirm Devices
When the system is powered up you will need to confirm the devices connected to the data bus.
To Confirm Devices on all types of RKP’s panel firmware version 14.06 onwards please use the following procedures. The method for each keypad is detailed.
N
For previous versions (14.04 and below) you can only confirm devices with an LCD RKP.