background image

INS647-3

7

Regulatory Information

The Premier External detector is protected by UK & 

International Designs.

Premier is a Trademark of Texecom Ltd.  

© 2015 Texecom Ltd. www.texe.com

 

MADE IN ENGLAND

7. Specifications & Standards

8. Physical Specifications

Specifications

Mounting Height:

1.0 - 1.4m, 1.2m nominal

Supply Voltage:

3 VDC  (2 x 1.5 VDC AA Lithium Batteries)

Battery Life

Up to 4 years

Current Drain (typical):

70µA 

Detection Method:

Dual, non-overlapping, digital PIR

Range:

12m max.  Adjustable to 8m, 5m and 2m

Tamper Detection:

Wall and case.  Sealed non-mechanical switch.

Start Up Time:

60 secs

Waterproof Coating:

Conformal

Supplier: 

Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK.

Texecom declares that this product complies with the requirements of the following directives:

• 1999/5/EC R&TTE Directive
• 2004/108/EC EMC Directive
• 2006/95/EC LVD Directive
• 2011/65/EU RoHS Directive

The product therefore meets all the requirements to enable it to be CE marked.

Weee Directive:

 2012/19/EC (WEEE directive): Products marked with this symbol cannot be disposed of as 

unsorted municipal waste in the European Union. For proper recycling, return this product to your local 
supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points. 
For more information see: www.recyclethis.info.

Maintenance:

 Test yearly by the installer

Warranty:

 2 year replacement warranty (exluding batteries)

Security grade: 

EN Grade 2  

Environmental class:

 Class IV  

Standards: 

EN50131-5-3

Disclaimer:

 The Premier External TD-W is not a complete alarm system, but only its part. Therefore Texecom does not 

accept any responsibility or liability for any damage that is claimed to be a result of an incorrect functioning of the 
Premier External TD-W detector. Texecom reserves the right to change the specification without a prior notice.

89mm

86.5mm

250mm

580g (20.5oz)

approx.

-35°C (-31°F) to 

+60°C (+140°F)

-35°C (-31°F) to 

+55°C (+131°F)

FM 35285

Battery Safety

•  Do not heat
•  Do not charge
•  Do not disassemble
•  Do not throw into a fire 
•  Do not short circuit
•  Replace with 2 x 1.5 VDC AA Lithium Batteries
•  Always observe local regulations when disposing 

of a battery

•  Detector will transmit low battery warning when 

battery needs replacing

Standards

EMC:

EN 55022: Class B.   EN50130-4:2011.    

EN61000-6-3 :2011

R&TTE:

EN300 220-2 V2.4.1

Environmental:

IP65

Frequency Band:

868.0 - 868.6 MHz 

Receiver:

Category 1, Class 2

Receiver LBT 

(Listen Before Talk)

Yes

Transmitter Duty Cycle:

868MHz<1%

Low Voltage Signal:

2.85V

Control Panel Compatability

Premier Elite version 2.11.00 and above with version 2.0.13 receiver and above. Premier International version 

12.02 and above with version 2.1.2 receiver above. Compatable with 

Ricochet

 Monitor 2.18.3 and above.

Содержание Premier External TD-W

Страница 1: ...Premier External TD W Installation Manual INS647 3...

Страница 2: ...ically start the learning sequence Device reverts back to programmed network if receiver is not in learn mode when replacing battery LEARN THE DEVICE TO THE SYSTEM BEFORE MOUNTING When in Auto Mode de...

Страница 3: ...ht Avoid pointing at swaying bushes trees and swaying clothes on a clothes line Try to install the detector so its detection area is terminated by building fences etc This will reduce the effect of ra...

Страница 4: ...le section must be securely fixed to the mounting surface Front View JP3 MODE Night Mode Detector only operates at night Day Night Mode Detector is always operating JP1 Pulse Count 4 Jumper Settings P...

Страница 5: ...ion 5m Coverage Position 2m Coverage Selected Range Side View Bottom of head unit To adjust the range of the detector rotate the circular section shown until the desired range is shown in the window N...

Страница 6: ...g With the range sensitivity coverage and pulse count set as desired enable the LEDs and walk through the area of protection Confirm the LEDs light by using the walk test mode shown in Premier Elite w...

Страница 7: ...n points For more information see www recyclethis info Maintenance Test yearly by the installer Warranty 2 year replacement warranty exluding batteries Security grade EN Grade 2 Environmental class Cl...

Страница 8: ...B4 4PW England Texecom Limited 2015 INS647 3 Technical Support UK Customers Tel 08456 300 600 Calls charged at 3 36 pence per minute from a BT landline Calls from other networks may vary International...

Отзывы: