INS647-3
7
Regulatory Information
The Premier External detector is protected by UK &
International Designs.
Premier is a Trademark of Texecom Ltd.
© 2015 Texecom Ltd. www.texe.com
MADE IN ENGLAND
7. Specifications & Standards
8. Physical Specifications
Specifications
Mounting Height:
1.0 - 1.4m, 1.2m nominal
Supply Voltage:
3 VDC (2 x 1.5 VDC AA Lithium Batteries)
Battery Life
Up to 4 years
Current Drain (typical):
70µA
Detection Method:
Dual, non-overlapping, digital PIR
Range:
12m max. Adjustable to 8m, 5m and 2m
Tamper Detection:
Wall and case. Sealed non-mechanical switch.
Start Up Time:
60 secs
Waterproof Coating:
Conformal
Supplier:
Texecom Ltd, St. Crispin Way, Haslingden, Lancashire, BB4 4PW, UK.
Texecom declares that this product complies with the requirements of the following directives:
• 1999/5/EC R&TTE Directive
• 2004/108/EC EMC Directive
• 2006/95/EC LVD Directive
• 2011/65/EU RoHS Directive
The product therefore meets all the requirements to enable it to be CE marked.
Weee Directive:
2012/19/EC (WEEE directive): Products marked with this symbol cannot be disposed of as
unsorted municipal waste in the European Union. For proper recycling, return this product to your local
supplier upon the purchase of equivalent new equipment, or dispose of it at designated collection points.
For more information see: www.recyclethis.info.
Maintenance:
Test yearly by the installer
Warranty:
2 year replacement warranty (exluding batteries)
Security grade:
EN Grade 2
Environmental class:
Class IV
Standards:
EN50131-5-3
Disclaimer:
The Premier External TD-W is not a complete alarm system, but only its part. Therefore Texecom does not
accept any responsibility or liability for any damage that is claimed to be a result of an incorrect functioning of the
Premier External TD-W detector. Texecom reserves the right to change the specification without a prior notice.
89mm
86.5mm
250mm
580g (20.5oz)
approx.
-35°C (-31°F) to
+60°C (+140°F)
-35°C (-31°F) to
+55°C (+131°F)
FM 35285
Battery Safety
• Do not heat
• Do not charge
• Do not disassemble
• Do not throw into a fire
• Do not short circuit
• Replace with 2 x 1.5 VDC AA Lithium Batteries
• Always observe local regulations when disposing
of a battery
• Detector will transmit low battery warning when
battery needs replacing
Standards
EMC:
EN 55022: Class B. EN50130-4:2011.
EN61000-6-3 :2011
R&TTE:
EN300 220-2 V2.4.1
Environmental:
IP65
Frequency Band:
868.0 - 868.6 MHz
Receiver:
Category 1, Class 2
Receiver LBT
(Listen Before Talk)
Yes
Transmitter Duty Cycle:
868MHz<1%
Low Voltage Signal:
2.85V
Control Panel Compatability
Premier Elite version 2.11.00 and above with version 2.0.13 receiver and above. Premier International version
12.02 and above with version 2.1.2 receiver above. Compatable with
Ricochet
Monitor 2.18.3 and above.