Texecom Premier Elite TTLCom Скачать руководство пользователя страница 3

Premier Elite TTLCom 

Installation Manual

 

INS640 

Wiring, Indication & Jumper position 

Wiring 

A typical installation should be wired as shown in the above diagram. No more than 6 expanders should be 

wired in daisy chain configuration.  

 

Some TTL convertors only have data in, data out and 0V, and use their own power supply. In 

this case the 12V on the convertor is not used. 

Indication 

The LED on the TTLCom PCB will flash when receiving data the same as the RX LED on the Control Panel 

Network. 

Jumper position 

Both jumper switches MUST be in the correct position on each board for the product to work correctly. The 

diagram above shows the 

IN/OUT

 configuration for a typical installation.  

Specifications 

Operating Voltage 

8 - 16V

DC

 

Current Consumption 

20mA 

Voltage levels on the TTL interface 

V

IL

< 1.8V 

V

IH

> 1.8V 

V

OH

> 4.7V 

V

OL

< 0.4V 

Maximum Cable Lengths

 

Network to TTLCom = 250Mtrs 
TTLCom to Fibre Modem = 1Mtr 

Standards 

 

Texecom declares that this product complies with the requirements of the 

following directives: 

 

2004/108/EC    EMC Directive 

 

2006/95/EC      LVD Directive 

 

2011/65/EU      RoHS Directive 

The product therefore meets all the requirements to enable it to be CE marked. 

 

Weee Directive

: 2012/19/EU (WEEE directive): Products marked with this symbol 

cannot be disposed of as unsorted municipal waste in the European Union. For 

proper recycling, return this product to your local supplier upon the purchase of 

equivalent new equipment, or dispose of it at designated collection points. For 

more information see: www.recyclethis.info. 

 

 