INS325-3 9/54
To install the detector:
1.Unwind the screw on the side of the detector until loose; the screw will be
retained in the product (
2.Lift detector lid out from the base and off the lugs at the opposite end to the
screw (
, item 2).
3.Fix the base to the ceiling between 2.4 m and 3.6 m (8 and 12 ft) from the floor.
For flat mounting use a minimum of 2 screws (DIN 7998) in any of the available
positions (
). Rear tamper pull-out needs to be secured to the mounting
surface to meet Grade 3 requirements.
). 5.Select the desired option
settings (
On either power-up or reapplication of the front cover the detector will
temporarily enter an auto-optimisation mode to adapt to it’s
environment. This will be shown by the LED’s flashing in sequence.
Allow 3 minutes for the optimisation to complete.
• During optimisation ensure that there are no obstructions in close proximity (<1m) to the
detector that will not be present during normal operation, as this could trigger a false masking
signal.