Premier Elite 32XPH-W Installation Instructions 

INS732 

2.

 

Premier Elite 32XPH-W 

Texecom  has  developed  a  new  method  of  wireless  security  signalling  based  on  the  concept  of  mesh 

networking. Mesh-networking is the process whereby every single wireless device is capable of receiving and 

retransmitting any signal from any other wireless device on the network. The size, scalability and range of the 

entire system are extended as wireless signalling is no longer limited by point-to point communications. The 

range of a Ricochet

®

 enabled wireless system is greater than previous systems, with multiple devices capable 

of  relaying  messages  to  and  from  even  the  most  remote  locations  in  a  building.  Each  Ricochet  enabled 

device provides signalling routes to and from control panels. If the wireless communication between devices 

weakens, the Ricochet network ‘self-heals’ and automatically re-routes communications via alternate Ricochet 

enabled  devices.  The  reliability  of  the  wireless  system  increases  as  more  Ricochet  devices  are  installed. 
SignalSecurity™  further  enhances  network  reliability  with  each  device  already  aware  of  the  number  of 

communication paths available to it. 

 

Firmware versions prior to those listed are NOT compatible. 

Control Panel 

Premier Elite 32XPH-W 

Legacy 

Ricochet 

Ricochet V2.xx 

** V2.10 > Premier Elite 

12/24/48/88/168 & 640* 

See Section 3 

N/A 

V2.10> 

V2.10> 

Multiple Expander Support 

It is now possible to add multiple expanders to the system allowing for greater flexibility in system design, and 

also taking wireless capability to new levels.  

Control Panel Capacity 

The table below details the maximum number of expanders and devices that may be used on the different 

control panels.  

Panel 

32XPH-W 

Expanders 

Devices 

Premier Elite 12-W & Live™ 

N/A 

N/A 

Premier Elite 24™ 

16 

Premier Elite 48™ 

32 

Premier Elite 48-W™ 

N/A 

32 

Premier Elite 88™ 

64 

Premier Elite 168™ 

128 

Premier Elite 640™ 

16 

512 

 

Premier Elite 32XPH-W take 4 address slots on the network. 

System Requirements 

To  enable all  of  the  advanced  functionality  and diagnostics  capability  Ricochet  the  following  are  minimum 

requirements:- 

 

Wintex™ Version 6 Build 16 or later 

 

Ricochet Monitor™ 0.2.15.00 or later 

 

Premier Elite™ Series V2.xx or later 

 

Premier Elite™ 32XPH-W Expanders V2.xx or later 

 

Expander firmware version can be found on the round green sticker located on the RH side of the PCB. 

Содержание Premier Elite 32XPH-W

Страница 1: ...Installation Manual Premier Elite 32XPH W INS732...

Страница 2: ...0 V2 09 24 48 88 168 640 Ricochet V2 xx 9 Introduction 9 Deleting Devices 10 Device Modes of Operation 10 Zone Types Attributes 11 Standalone Mode 12 Standalone Operation 12 This table shows two examp...

Страница 3: ...iability with each device already aware of the number of communication paths available to it Firmware versions prior to those listed are NOT compatible Control Panel Premier Elite 32XPH W Legacy Ricoc...

Страница 4: ...l of the devices have been learnt they will need placing in their desired location this should be done by installing devices closest to the expander first and then working outwards so that the last de...

Страница 5: ...into commission mode and digitally attenuates the receiver signal by 15Db 6 Programming LED s Allows programming of devices directly to the receiver in conjunction with the learn switch Standalone mod...

Страница 6: ...ng the expander Connect the expander to the control panel using 4 core cable as follows Expander Control Panel Description 12V Supply 0V Supply T T Transmit Data R R Receive Data The networks are made...

Страница 7: ...N A N A N A N A N A N A N A N A N A N A N A Expander Address 1 5 N A N A N A N A N A N A N A N A N A N A N A N A N A N A Premier Elite 168 Exp 1 Exp 2 Exp 1 Exp 2 N A N A N A N A N A N A N A N A N A...

Страница 8: ...l dictate which next free zone is chosen to learn too When all device slots have been used the following screen will be shown All Devices Learnt Pressing the N Nkey will return you to the Ricochet lea...

Страница 9: ...ce Zone N E n n U N N If all devices are deleted from the system the following will be shown All Devices Deleted Pressing the N Nkey will return you to the Ricochet learn menu pressing the key will en...

Страница 10: ...sed on devices which are required to signal at all times and is the default setting for perimeter detection devices such as Contacts and Shock sensors PA Buttons Auto Mode When in Auto Mode devices po...

Страница 11: ...the Zone Setup menu please follow the diagram on the next page Zone 00 Panel0 Not sed Yes to Select Zone Setup y Zone 00 P0 0 Not sed R Zone 00 Learn Learning 20s Zone 00 Learn P R P 0 0 y Zone 00 P0...

Страница 12: ...tem Free device slots are indicated by the corresponding LED s flashing if the LED s do not flash then that slot is already occupied by another device Depress the Learn switch on the device and insert...

Страница 13: ...igures outputs to be momentary When off outputs latch and may be cleared using the Function switch 7 OR 13 Zone 7 SL350 RX Zone 4 PIR 14 Zone 7 SL350 TX Empty 8 OR 15 Zone 8 SL350 RX Zone 4 PIR 16 Zon...

Страница 14: ...normally be seen on a recently powered up system wait 15 minutes from power up before checking the diagnostics information Signal Security Zone 00 Shock This display shows information relating to sig...

Страница 15: ...ew Event Log YES to Select Engineer tils y U Zone 00 Shock Status aaaSpdtt Zone 00 Shock P Zone 00 Shock P C Zone 00 Not Ricochet C B B ser000 Ricochet Not Ricochet U ser002 Ricochet Not connected Zon...

Страница 16: ...nabled when the expander is in tamper When in commission mode the RF signal is attenuated by 6 dB and will reject weak signals This means that when devices are placed into their final locations and co...

Страница 17: ...he default setting for the Impaq Contact W and Impaq Plus W For example a Impaq Contact W on a door which you need to know is opened regardless of system state or devices such as PA buttons smoke dete...

Страница 18: ...ature 10 C 14 F to 50 C 122 F Storage Temperature 20 C 4 F to 60 C 140 F Maximum Humidity 95 non condensing EMC Environment Residential Commercial Light Industrial or Industrial Physical Dimensions 17...

Страница 19: ...Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the Premier Elite 32XPH W expander is covered by a two y...

Страница 20: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1706 23387...

Отзывы: