Texecom Premier Elite 32XPH-W Скачать руководство пользователя страница 17

 

Premier Elite 32XPH-W Installation Instructions 

INS732 

17 

8.

 

System Attributes 

Polling 

Polling occurs between the devices and the receiver at a pre-determined interval of 15 minutes. This helps to 

conserve battery life. Poll intervals are set to 4 minutes when the system is in Commission Mode. Please see 

page 16 for details. The standard poll time is not adjustable. If the system is powered down for more than 1 

hour, the devices will go into an Offline Mode to conserve battery life, in this case it can take up to 2 hours for 

all  devices  to  come  back  online,  alternatively  each  device  should  have  its  tamper  circuit  opened  to  force 

communications. When forcing the devices to come back online the same setup principles should be used 

and  devices  closest  to  the  receiver  should  be  activated  first,  this  will  again  allow  the  mesh  network  to  be 

established.   

System Devices 

Auto Mode 

When  in  Auto  Mode,  devices  poll  at  15  minute  intervals.  Following  activation,  devices  will  not  transmit  the 

same activation again for a period of 3 minutes. 

Always Awake 

This mode should only be used on devices which are required to signal at all times and is the default setting 
for the Impaq Contact-W and Impaq Plus-W. For example a Impaq Contact-W on a door which you need to 

know is opened, regardless of system state; or devices such as PA buttons & smoke detectors which have 

been  connected  to  the  inputs  of  the  Magnetic  Contact.  The  number  of  devices  on  a  system  in  this  mode 

should be kept to a minimum. 

Device Specific 

This  mode  is  assigned  to  devices  that  need  to operate  in  a  specific  way  and  should  not  be  changed.  Life 

safety devices and sounders will typically use this mode. 

Hybrid Mode (V2.xx) 

Hybrid  mode  is  used  to  control  the  reporting  functions  for  devices. When  in  this  mode  devices are  asleep 

when the system is unset, and are woken up by the control panel at the point of arming. When the system is 

disarmed the devices will be put back to sleep.  

Expander O/P Mode 

Expander O/P modes are for future use and should not be used with any of the devices listed above. 

 

On very large systems (100 d) a small delay may be experienced when arming the system, this is normal 

as the expanders on the system wake up the relevant devices. 

 

Premier Elite DT-W should ALWAYS be used in Hybrid mode, failure to do this will have an adverse effect on 

battery life. 

 

as this is a dynamic bi-directional system any device which is Always Awake has the capability to shorten battery 

life of other devices.

 

Содержание Premier Elite 32XPH-W

Страница 1: ...Installation Manual Premier Elite 32XPH W INS732...

Страница 2: ...0 V2 09 24 48 88 168 640 Ricochet V2 xx 9 Introduction 9 Deleting Devices 10 Device Modes of Operation 10 Zone Types Attributes 11 Standalone Mode 12 Standalone Operation 12 This table shows two examp...

Страница 3: ...iability with each device already aware of the number of communication paths available to it Firmware versions prior to those listed are NOT compatible Control Panel Premier Elite 32XPH W Legacy Ricoc...

Страница 4: ...l of the devices have been learnt they will need placing in their desired location this should be done by installing devices closest to the expander first and then working outwards so that the last de...

Страница 5: ...into commission mode and digitally attenuates the receiver signal by 15Db 6 Programming LED s Allows programming of devices directly to the receiver in conjunction with the learn switch Standalone mod...

Страница 6: ...ng the expander Connect the expander to the control panel using 4 core cable as follows Expander Control Panel Description 12V Supply 0V Supply T T Transmit Data R R Receive Data The networks are made...

Страница 7: ...N A N A N A N A N A N A N A N A N A N A N A Expander Address 1 5 N A N A N A N A N A N A N A N A N A N A N A N A N A N A Premier Elite 168 Exp 1 Exp 2 Exp 1 Exp 2 N A N A N A N A N A N A N A N A N A...

Страница 8: ...l dictate which next free zone is chosen to learn too When all device slots have been used the following screen will be shown All Devices Learnt Pressing the N Nkey will return you to the Ricochet lea...

Страница 9: ...ce Zone N E n n U N N If all devices are deleted from the system the following will be shown All Devices Deleted Pressing the N Nkey will return you to the Ricochet learn menu pressing the key will en...

Страница 10: ...sed on devices which are required to signal at all times and is the default setting for perimeter detection devices such as Contacts and Shock sensors PA Buttons Auto Mode When in Auto Mode devices po...

Страница 11: ...the Zone Setup menu please follow the diagram on the next page Zone 00 Panel0 Not sed Yes to Select Zone Setup y Zone 00 P0 0 Not sed R Zone 00 Learn Learning 20s Zone 00 Learn P R P 0 0 y Zone 00 P0...

Страница 12: ...tem Free device slots are indicated by the corresponding LED s flashing if the LED s do not flash then that slot is already occupied by another device Depress the Learn switch on the device and insert...

Страница 13: ...igures outputs to be momentary When off outputs latch and may be cleared using the Function switch 7 OR 13 Zone 7 SL350 RX Zone 4 PIR 14 Zone 7 SL350 TX Empty 8 OR 15 Zone 8 SL350 RX Zone 4 PIR 16 Zon...

Страница 14: ...normally be seen on a recently powered up system wait 15 minutes from power up before checking the diagnostics information Signal Security Zone 00 Shock This display shows information relating to sig...

Страница 15: ...ew Event Log YES to Select Engineer tils y U Zone 00 Shock Status aaaSpdtt Zone 00 Shock P Zone 00 Shock P C Zone 00 Not Ricochet C B B ser000 Ricochet Not Ricochet U ser002 Ricochet Not connected Zon...

Страница 16: ...nabled when the expander is in tamper When in commission mode the RF signal is attenuated by 6 dB and will reject weak signals This means that when devices are placed into their final locations and co...

Страница 17: ...he default setting for the Impaq Contact W and Impaq Plus W For example a Impaq Contact W on a door which you need to know is opened regardless of system state or devices such as PA buttons smoke dete...

Страница 18: ...ature 10 C 14 F to 50 C 122 F Storage Temperature 20 C 4 F to 60 C 140 F Maximum Humidity 95 non condensing EMC Environment Residential Commercial Light Industrial or Industrial Physical Dimensions 17...

Страница 19: ...Texecom products are designed for reliable trouble free operation Quality is carefully monitored by extensive computerised testing As a result the Premier Elite 32XPH W expander is covered by a two y...

Страница 20: ...Lancashire BB4 4PW England Technical Support UK Customers Tel 08456 300 600 Calls charged at local rate from a BT landline Calls from other networks may vary International Customers Tel 44 1706 23387...

Отзывы: