Texecom INS555-3 Скачать руководство пользователя страница 2

Premier Elite Series User Guide 

INS555-3 

EN. Overview 

 Introduction 

Users of the alarm system will be assigned a unique 4, 5 or 6 digit User code, and may be assigned a Proximity Tag or a 

SmartKey™

Codes, Tags & 

SmartKey™

 are used to arm and disarm the system. Some  User codes  can also access additional options such as, 

system tests and omitting zones. Keypads will be installed throughout the premises, usually one at each entry/exit door. The keypads 

are used to perform all of the system operations i.e. Arming, Disarming etc.  Most User codes can be used at any keypad on the system. 

However, Local Users will only be able to use certain keypads on the system. 

Keys 

 

 

 

 

 

 

LED 

 

 

 

 

 

 

ICONS 

 

UK English 

 

English 

 

 

 

Power 

 

 

Ready 







 

 

Armed/Info

 

 

OK 

Ready 







 

 

Omit

 

 

 

Service 







 







 

SmartKey™ 







 

Buttons 

 

Function 

 

LED's 

 







 

 

Power 

 

 

Status 







 

 

Arm 

 

Disarm 







 

 

Part Arm 

 

Part Arm 







 

 

Disarm 

 

Arm 

The Keypad Emergency Keys 

In case of emergency, the alarm system can provide three immediate emergency alarms by pressing and holding two specific keys for 

two seconds. 

UK Only 

 

Non UK 

 

The  emergency  keys  can  be  enabled/disabled 

for  each  keypad  on  the  system.  The  Panic 

alarm  can  be  programmed  for  either  audible 

or  silent  operation.  The  Panic  alarm  can  be 

programmed  for  either  instant  or  delayed 

operation

 

 

Emergency Alarm 

Press Keys 

 

Emergency Alarm 

Press Keys 

Panic Alarm (PA) 

 

&

 

 

Fire 

 

&

 

 

Fire 

 

&

 

 

Panic Alarm (PA) 

 

&

 

 

Medical 

 

&

 

 

Medical 

 

&

 

 

The Keypad Quick Arm Keys 

The ‘Quick Arm’ keys allow the system to be armed without having to enter a User code first.

 

 

The ‘Quick Arm’ keys will only work if the keypad has been programmed to allow arming in this way

To FULL arm the system, press 

.To PART arm the system, press

 

 or 

 followed by

 

Keypad Lock 

The keys on the keypad can be locked to prevent unwanted access to the system. 

 

The Emergency keys will NOT operate with the keys locked.

 

 

To Lock the keys press

 

 

and

 

 

together. 

To Unlock the keys, press

 

 

and

 

 

together again. 

LED Indicators 

Five LED indicators have been provided to indicate the status of the system. 

LED 

Status 

Meaning 

Power 

On 

AC mains is present on the control panel 

Flashing 

AC Mains is not present, the control panel is running on the standby battery 

Service 

On 

The system requires attention, contact your installer 

Off 

The system does NOT require attention 

Ready 

On 

All zones are secure and the system is ready to be armed 

Off 

One or more zones are active 

Flashing 

The system has 

zones (with the ‘Force Omit’ attribute) that are active

 

Info. 

On 

The system is armed (can also be programmed for other indications) 

Off 

The system is unarmed (can also be programmed for other indications) 

Omit 

On 

One or more zones are omitted 

Off 

No zones are omitted 

Содержание INS555-3

Страница 1: ...e Set 1 Pages EN Premier Elite Series User Guide 2 7 FR Premier Elite Series Guide de l utilisateur 8 13 NL Premier Elite Serie Gebruikersgids 14 19 DE Benutzerhandbuch Serie Premier Elite 20 25 Your...

Страница 2: ...instant or delayed operation Emergency Alarm Press Keys Emergency Alarm Press Keys Panic Alarm PA Fire Fire Panic Alarm PA Medical Medical The Keypad Quick Arm Keys The Quick Arm keys allow the system...

Страница 3: ...the exit tone will stop To PART Arm the System The system is PART Armed when ONE OR MORE zones have been left OFF omitted i e the landing or a bedroom The system is only Part Armed when zones are omi...

Страница 4: ...continue to flash 1 Enter a valid User code The internal and external sounders will stop the external strobe will continue to flash and the number of the zone that caused the Arm Fail will be display...

Страница 5: ...ode that has been given to you 5 Press If the Anti code is correct the keypad will bleep to indicate that the system has been reset and the display will return to normal To OMIT Zones It is possible t...

Страница 6: ...to a MULTIPLE action 4 The control panel will log which User TAG has been presented Programming Proximity TAGS Programming a Proximity TAG will depend on which type of control panel and what version...

Страница 7: ...et Enter a valid User code Press Reset Contact Your Alarm Receiving Centre Quote 4 digit code shown on display Enter 4 digit code given by Receiving Centre Press Yes To Omit Zones Enter a valid User c...

Страница 8: ...du clavier peuvent tre bloqu es pour emp cher un acc s ind sir au syst me Les touches d urgence ne fonctionnent pas lorsque les touches sont bloqu es Pour bloquer les touches appuyer sur et en m me t...

Страница 9: ...s curis s que toutes les portes et fen tres non ject es sont bien ferm es et que le t moin Pr t est allum 2 Entrez un code utilisateur valide 3 Appuyez sur 4 Utilisez les touches pour s lectionner l...

Страница 10: ...arr tent Le flash externe continue de flasher et le num ro de la zone qui a caus la faute s affichera 2 Entrez un code utilisateur valide et appuyez sur Rendre une alarme silencieuse Lorsqu une alarm...

Страница 11: ...n marche et l affichage redevient normal jection de Zones Il est possible d jecter des zones individuellement lorsque vous armez par exemple si la zone est en faute Les utilisateurs avec acc s cette f...

Страница 12: ...action unique compar une action multiple 4 La centrale d alarme enregistre quel Tag Utilisateur a t pr sent Programmer les TAGS de proximit La programmation des TAGs de proximit d pend de la centrale...

Страница 13: ...e utilisateur valide Appuyez sur RAZ Rendre une Alarme silencieuse Entrez un code utilisateur valide Remise en marche apr s alarme Entrez un code utilisateur valide Appuyez sur RAZ Remise en marche In...

Страница 14: ...e toetsen op het bedienpaneel kunnen vergrendeld worden om ongewenste toegang tot het systeem onmogelijk te maken De noodtoetsen werken NIET als de toetsen vergrendeld zijn Voor het vergrendelen van d...

Страница 15: ...wis u ervan dat het gebouw veilig is alle niet overgeslagen ramen en deuren gesloten en de Klaar led brandt 2 Voer een geldige gebruikerscode in 3 Druk op 4 Gebruik de toetsen om het gewenste Gedeelte...

Страница 16: ...innen en buitensirenes al gestopt zijn maar het buitenflitslicht flitst nog steeds Als de alarminformatie wordt weergegeven druk dan op de SCROLL toets om de weergave te vertragen en met de hand door...

Страница 17: ...t aanzetten bijv als een zone in fout in storing is Gebruikers die toegang hebben tot deze functie kunnen alleen zones overslaan die zijn geprogrammeerd als Overbrugbaar Als een zone kan worden overbr...

Страница 18: ...ges Het programmeren van een badge is afhankelijk van het type bedieningspaneel en de ge nstalleerde softwareversie uw installatiebedrijf kan u vertellen of u badges kunt gebruiken met uw systeem Het...

Страница 19: ...kerscode in Druk op Reset Een alarm tot zwijgen brengen Voer een geldige gebruikerscode in Resetten na een alarm Voer een geldige gebruikerscode in Druk op Reset Resetten door technicus Neem contact o...

Страница 20: ...Tastenfeldes k nnen gesperrt werden um unerw nschte Eingriffe in das System zu verhindern Wenn die Tasten gesperrt sind funktionieren auch die Notfalltasten NICHT Zum Sperren der Tasten dr cken Sie u...

Страница 21: ...haltung programmiert werden Ihr Installateur hat das System m glicherweise so programmiert dass es teilweise scharfgeschaltet werden kann indem Sie einfach oder gefolgt von dr cken In diesem Fall ist...

Страница 22: ...Informationen zum Vermeiden von Scharfschaltungsfehlern finden Sie auf Seite 25 Falls Sie nicht anwesend waren als sich der Scharfschaltungsfehler ereignet hat oder wenn Sie den Scharfschaltungsfehle...

Страница 23: ...ieses Benutzerhandbuchs angegebene Telefonnummer an Zur cksetzen mithilfe eines ANTI CODES Wenn das System so programmiert wurde dass es nach einem Alarm durch Eingabe eines Anti Codes zur ckgesetzt w...

Страница 24: ...sicheren Ort notieren Wenn Sie Ihren Code vergessen haben muss ein Techniker bei Ihnen vor Ort einen neuen Code f r Sie programmieren F r diesen Vorgang k nnen Anfahrtskosten anfallen 1 Geben Sie den...

Страница 25: ...ong dr cken um System stumm scharfzuschalten oder Individuelle Bereiche scharfschalten G ltigen Benutzercode eingeben Area dr cken Gew nschten Bereich ber die Tasten 1 8 ausw hlen Ja dr cken oder Gong...

Страница 26: ...26 INS555 3...

Страница 27: ...INS555 3 27...

Страница 28: ...Texecom Limited Bradwood Court St Crispin Way Haslingden Lancashire BB4 4PW England Texecom Limited 2015 INS555 3 Your local installer www eaglesecuritysolutions co uk...

Отзывы: