![Texecom ComGSM Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/texecom/comgsm/comgsm_installation-manual_1097348003.webp)
ComGSM Module
Installation Manual
INS315
3
Antenna connection
Tamper switch
Com1 data connection to
Premier
control panel
Engineer keypad connector (for future use)
Option switches (see table below)
Status LED’s (see table below)
Audio connector (for future use)
Heartbeat LED
SIM card socket
Option Switches
The option switches (
) function as follows:
Switch
Off
On
1
When the tamper is open, the GSM
signal is reported as NO signal
GSM signal level is reported as normal
2
For future use – leave in OFF position
3
For future use – leave in OFF position
4
Toggle to perform a Reset
Status LEDs
The three status LED’s (
) indicate the following:
LED
Off
On
Flashing
1
GSM NOT Ready
GSM Ready
GSM Communicating
2
Panel NOT Ready
Panel Ready
Panel Communicating
3
No GSM Signal
Dim = Low Signal
Bright = Good Signal
N/A
Installation
The
ComGSM
module should be installed as close to the control panel as possible, so
that the harness lead supplied with the unit is able to plug onto the control panel
communication port.
1.
Route the harness lead into the module housing using the top left cable
entry and plug the connector onto COM1 (
).