www.texas.dk
23
9. Trouble shooting
Problem
Possible cause
Solution
The air cannot get out
because the hose is twisted
Straighten out the hose
Air buble in the draghead
Wait in 60 seconds until the
pump has aired automatically
through the air valve. If
necessary disconnect the
power
The turbine housing is
blocked
Clean the turbine housing
The pump runs but it doesn t
suck up water.
When the pump starts, the
water level falls below lowest
suction level
Lower the pump further
down (see point 9)
The pump is overheated,
therefore the thermal cut-off
has switched the pump off
Disconnect the power supply
and clean the turbine
housing (see point 8). Make
sure the water temperature
does not exceed 35°C
The power supply is
disconnected
Control devices and hose
connections
The pump does not start or
stops suddenly
Large particles and stones
have blocked the draghead
Disconnect the power supply
and clean the draghead (see
point 8)
The pump runs but the
pumped water level declines
The draghead is blocked
Disconnect the power supply
and clean the draghed (see
point 8)
Note!!! Any reponsibility caused by incorrect repair, use of unoriginal or non-
approved parts is renounced. The same is valid for unoriginal or non- approved
accessories.
10. Construction components (see illustration B and C)
1. Electric cable
2. Handle
3. Swimmer contact arm
4. Air escape valve
5. Swimmer
6. Draghead
7. Universal hose connection
8. Slotted screw
9. Turbine