Power
Supply #1
12V:
0.05A
CHA
CHB
EVM
Function
Generator
Oscilloscope
+
DMM #1
DC Current
Test Summary
5
SLUUCB3 – June 2020
Copyright © 2020, Texas Instruments Incorporated
Using the UCC27288EVM
4.3.4
Oscilloscope Settings
details the oscilloscope settings.
Table 3. Oscilloscope Settings
Bandwidth
Coupling
Termination
Scale Settings
Inverting
Channel A
500 MHz or above
DC
1 M
Ω
or automatic
10 × or automatic
OFF
Channel B
4.3.5
Bench Setup Diagram
The bench setup diagram includes the function generator and oscilloscope connections.
Use the following connection procedure, refer to
.
•
First, make sure the output of the function generator and power supplies are disabled before
connection.
•
Apply function generator channel-A on HI_IN-GND.
•
Apply function generator channel-B on LI_IN-GND.
•
Power supply #1: apply positive lead to current input of DMM #1 and current output of DMM #1 to test
point VCC; apply negative lead to test point GND.
•
Apply oscilloscope channel-1 probes on HO LD-HS, minimizing the loop area as much as possible.
Note the scope ground is connected to HS test point.
•
Apply oscilloscope channel-2 probes on LO LD-GND, minimizing the loop area as much as possible.
Figure 1. Bench Setup Diagram and Configuration