2.6.10
AGC
within the block diagram for the full TSC2117
.
www.ti.com
EVM + PC
The TSC2117 has an automatic gain control module, which is accessible by an active object labeled AGC
Clicking on the AGC active objects opens the AGC Dialog:
Figure 12. Automatic Gain Control
If the AGC is enabled, the TSC2117 will adjust the gain of the analog audio input signal amplifier so that
the input signal level for input signal amplitudes above the noise threshold approximates the target level.
•
The main display in the AGC dialog shows the Amplitude of the ADC output data in decibel with 0dB
equal to a full scale signal.
•
–
The target level line can be adjusted using the mouse pointer. It will change color to red if it the
mouse pointer is in the vicinity, indicating that it can be moved (click and drag).
–
The noise threshold line is also adjustable
•
The small display on the left shows the ADC output data
•
The AGC Gain field shows the applied gain (if the AGC is enabled) and allows setting a maximum gain
using the slider.
Advanced AGC controls are available by clicking the More button. This will reveal further controls to adjust
various AGC parameters.
SLAU282 – April 2009
TSC2117EVM-K
17