background image

60

TRF7960A

SLOS732G – JUNE 2011 – REVISED MARCH 2020

www.ti.com

Submit Documentation Feedback

Product Folder Links:

TRF7960A

Detailed Description

Copyright © 2011–2020, Texas Instruments Incorporated

6.14.1.5 FIFO Control Registers

6.14.1.5.1 FIFO Status Register (0x1C)

Table 6-39

describes the bit fields of the FIFO Status register. This register contains the low nibbles of the

complete bytes to be transferred through the FIFO and information about a broken byte and the number of
bits to be transferred from it.

Table 6-39. FIFO Status Register (0x1C)

BIT NO.

BIT NAME

FUNCTION

DESCRIPTION

B7

RFU

B7 = 0

Reserved for future use (RFU)

B6

Fhil

FIFO level high

Indicates that 9 bytes are already in the FIFO (for RX) (also see
register 0x0C bit 5)

B5

Flol

FIFO level low

Indicates that only 3 bytes are in the FIFO (for TX) (also see register
0x0C bit 5)

B4

Fove

FIFO overflow error

Too many bytes were written to the FIFO

B3

Fb3

FIFO bytes fb[3]

Bits B0:B3 indicate how many bytes that are loaded in FIFO were
not read out yet (displays N – 1 number of bytes). If 8 bytes are in
the FIFO, this number is 7 (also see register 0x0C bit 6).

B2

Fb2

FIFO bytes fb[2]

B1

Fb1

FIFO bytes fb[1]

B0

Fb0

FIFO bytes fb[0]

6.14.1.5.2 TX Length Byte1 Register (0x1D) and TX Length Byte2 Register (0x1E)

Table 6-40

describes the bit fields of the TX Length Byte1 register. This register contains the high two

nibbles of complete intended bytes to be transferred through FIFO.

Default Value:

0x00, set at POR and EN = 0. The register is also automatically reset at TX EOF.

Table 6-40. TX Length Byte1 Register (0x1D)

BIT NO.

BIT NAME

FUNCTION

DESCRIPTION

B7

Txl11

Number of complete byte bn[11]

High nibble of complete intended bytes to be transmitted

B6

Txl10

Number of complete byte bn[10]

B5

Txl9

Number of complete byte bn[9]

B4

Txl8

Number of complete byte bn[8]

B3

Txl7

Number of complete byte bn[7]

Middle nibble of complete intended bytes to be transmitted

B2

Txl6

Number of complete byte bn[6]

B1

Txl5

Number of complete byte bn[5]

B0

Txl4

Number of complete byte bn[4]

Содержание TRF7960A

Страница 1: ...mity and vicinity identification systems The reader is configured by selecting the desired protocol in the control registers Direct access to all control registers allows fine tuning of various reader...

Страница 2: ...grammable auxiliary voltage regulator delivers up to 20 mA to supply an MCU and additional external circuits within the reader system To evaluate the latest products in the TRF79xx product family TRF7...

Страница 3: ...unctional Block Diagram 11 6 2 Power Supplies 11 6 3 Supply Arrangements 12 6 4 Supply Regulator Settings 13 6 5 Power Modes 14 6 6 Receiver Analog Section 17 6 7 Receiver Digital Section 18 6 8 Oscil...

Страница 4: ...20 Texas Instruments Incorporated 2 Revision History NOTE Page numbers for previous revisions may differ from page numbers in the current version Changes from May 18 2017 to March 11 2020 Page Removed...

Страница 5: ...ess Connectivity Connect more with the industry s broadest wireless connectivity portfolio Products for NFC RFID TI provides one of the industry s most differentiated NFC and RFID product portfolios a...

Страница 6: ...ed supply 2 7 V to 5 V normally connected to VDD_PA pin 4 4 VDD_PA INP Supply for PA normally connected externally to VDD_RF pin 3 5 TX_OUT OUT RF output selectable output power 100 mW or 200 mW with...

Страница 7: ...O_7 BID I O pin for parallel communication MOSI for serial communication SPI 25 EN2 INP Selection of power down mode If EN2 is connected to VIN then VDD_X is active during power down mode 2 for examp...

Страница 8: ...ice 5 Specifications 5 1 Absolute Maximum Ratings 1 over operating free air temperature range unless otherwise noted 2 MIN MAX UNIT Input voltage range VIN 0 3 6 V Maximum current IIN 150 mA Maximum o...

Страница 9: ...y current without antenna driver current Oscillator regulators RX and AGC are active TX is off 10 5 14 mA ION2 Supply current in TX half power Oscillator regulators RX AGC and TX active POUT 100 mW 70...

Страница 10: ...depends on the capacitive load Maximum SPI clock speed should not exceed 10 MHz This clock speed is acceptable only when external capacitive load is less than 30 pF MISO driver has a typical output r...

Страница 11: ...Description Copyright 2011 2020 Texas Instruments Incorporated 6 Detailed Description 6 1 Functional Block Diagram Figure 6 1 shows the functional block diagram Figure 6 1 Functional Block Diagram 6 2...

Страница 12: ...used per reference schematics When configured for 3 V manual operation the VDD_A output can be set from 2 7 V to 3 4 V in 100 mV steps see Table 6 2 NOTE The configuration of VDD_A and VDD_X regulator...

Страница 13: ...s VSS pin 10 the analog negative supply is VSS_A pin 15 the logic negative supply is VSS_D pin 29 the RF output stage negative supply is VSS_PA pin 6 and the negative supply for the RF receiver VSS_RX...

Страница 14: ...0 0 0 VDD_RF 2 7 V VDD_A 2 7 V VDD_X 2 7 V The regulator configuration function adjusts the regulator outputs by default to 250 mV below VIN level but not higher than 5 V for VDD_RF 3 4 V for VDD_A an...

Страница 15: ...Mode 4 full power 5 VDC x 1 21 07 On On On x On 130 23 20 to 25 s Mode 4 full power 3 3 VDC x 1 20 07 On On On x On 67 18 Mode 3 half power 5 VDC x 1 31 07 On On On x On 70 20 20 to 25 s Mode 3 half p...

Страница 16: ...the reader stays active If the EN input is not set high EN 0 within 100 s after the SYS_CLK output is switched from auxiliary clock 60 kHz to high frequency clock derived from the crystal oscillator...

Страница 17: ...default MUX setting is RX_IN1 connected to the main receiver and RX_IN2 connected to the auxiliary receiver To determine the signal quality the response from the tag is detected by the main pin RX_IN...

Страница 18: ...process special signals such as the start of frame SOF end of frame EOF start of communication and end of communication are automatically removed The parity bits and CRC bytes are also checked and re...

Страница 19: ...the start of tag response If there is no tag response in the defined time an interrupt request is sent and a flag is set in the IRQ Status register 0x0C This enables the external controller to be rel...

Страница 20: ...e communication to the Tag this means the TX must be on Bit 1 in the Chip Status Control register 0x00 defines if internal RSSI or the external RSSI value is stored in the RSSI Levels and Oscillator S...

Страница 21: ...rolled by the Chip Status Control register 0x00 and the EN and EN2 signals The oscillator generates the RF frequency for the RF output stage and the clock source for the digital section The buffered c...

Страница 22: ...he modulation type ASK or OOK at pin 12 External control of the modulation type is made possible only if enabled by setting B6 in the Modulator and SYS_CLK Control register 0x09 to 1 In normal operati...

Страница 23: ...43 B protocol ISO14443A High Bit Rate and Parity Options register 0x03 This register enables the use of different bit rates for RX and TX operations in ISO IEC 14443 high bit rate protocol Besides tha...

Страница 24: ...he master device The MCU initiates all communications with the TRF7960A The TRF7960A makes use of the Interrupt Request IRQ pin in both parallel and SPI modes to prompt the MCU for servicing attention...

Страница 25: ...ional data the address is incremented by one Continuous mode can be used to write to a block of control registers in a single stream without changing the address for example setup of the predefined st...

Страница 26: ...the format of a continuous address register read and Figure 6 5 and Figure 6 6 show examples Table 6 8 Continuous Address Mode Start Adr x Data x Data x 1 Data x 2 Data x 3 Data x 4 Data x n StopCont...

Страница 27: ...Table 6 9 lists the format of a single address register read and Figure 6 7 and Figure 6 8 show examples Table 6 9 Noncontinuous Address Mode Single Address Mode Start Adr x Data x Adr y Data y Adr z...

Страница 28: ...keeps track of the number of bytes loaded into the FIFO If the number of bytes in the FIFO is n the register value is n 1 number of bytes in FIFO register If 8 bytes are in the FIFO the FIFO counter b...

Страница 29: ...ata or remove the data as necessary The MCU also checks the number of data bytes to be sent so as to not surpass the value defined in TX length bytes The MCU also signals the transmit logic when the l...

Страница 30: ...he MCU at the end of the receive operation if the receive data string was shorter than or equal to 8 bytes The MCU receives the interrupt request then checks to determine the reason for the interrupt...

Страница 31: ...ta to the FIFO if needed At the end of the transmit operation an interrupt is sent to inform the MCU that the task is complete 6 12 6 Serial Interface Communication SPI When an SPI interface is used I...

Страница 32: ...Read Figure 6 15 Dummy Read Using SPI With SS 6 12 6 1 Serial Interface Mode Without Slave Select SS The serial interface without the slave select pin must use delimiters for the start and stop condit...

Страница 33: ...irst Figure 6 17 SPI With Slave Select Timing The read command is sent out on the MOSI pin MSB first in the first eight clock cycles MOSI data changes on the falling edge and is validated in the reade...

Страница 34: ...lt operation Full sequences for other settings and protocols can be downloaded from http www ti com lit zip sloc240 Figure 6 20 Inventory Command Sent From MCU to TRF7960A The TRF7960A reads these byt...

Страница 35: ...TX is complete This is followed by dummy clock and reset of FIFO with dummy clock Then if a tag is in the field and no error is detected by the reader a second interrupt is expected and occurs in this...

Страница 36: ...byte is 0x00 for no error The next byte is the DSFID usually shipped by manufacturer as 0x00 then the UID shown here up to the next most significant byte MSByte the MFG code 0x07 to indicate TI silico...

Страница 37: ...ght 2011 2020 Texas Instruments Incorporated Figure 6 24 IRQ With One Byte in FIFO TI recommends resetting the FIFO after receiving data Additionally the RSSI value of the tag can be read out at this...

Страница 38: ...control over the RF modulation through the MOD input This mode is provided so that the application can implement a protocol that has the same bit coding as one of the protocols implemented in the read...

Страница 39: ...ion 0x20 for 6 78 MHz clock and ASK 10 modulation 0x22 for 6 78 MHz clock and ASK 7 modulation 0x23 for 6 78 MHz clock and ASK 8 5 modulation 0x24 for 6 78 MHz clock and ASK 13 modulation 0x25 for 6 7...

Страница 40: ...r the RF modulation through the MOD input Figure 6 28 Control of RF Modulation Using MOD The microcontroller is responsible for generating data according to the coding specified by the particular stan...

Страница 41: ...cription Copyright 2011 2020 Texas Instruments Incorporated Figure 6 29 Receive Data Bits and Framing Level ISO IEC 14443 A Step 7 Exit direct mode 0 When an EOF is received data transmission is over...

Страница 42: ...values from Table 6 11 are substituted in Table 6 12 Bits 0 to 4 Also the most significant bit MSB in Table 6 12 must be set to 1 Table 6 12 Address Command Word Bit Distribution BIT DESCRIPTION BIT F...

Страница 43: ...ceiver command puts the digital part of receiver bit decoder and framer in reset mode This is useful in an extremely noisy environment where the noise level could otherwise cause a constant switching...

Страница 44: ...ltage in the RF_IN1 input and RSSI code respectively NOTE If the command is executed immediately after power up and before any communication with tag was performed the command must be preceded by the...

Страница 45: ...2 0x04 TX Timer Setting H byte R W Section 6 14 1 2 3 0x05 TX Timer Setting L byte R W Section 6 14 1 2 4 0x06 TX Pulse Length Control R W Section 6 14 1 2 5 0x07 RX No Response Wait R W Section 6 14...

Страница 46: ...ides user direct access to AFE direct mode 0 or lets the user add custom framing direct mode 1 Bit 6 of the ISO Control register must be set before entering direct mode 0 or 1 0 ISO mode default Uses...

Страница 47: ...be made in register 0x02 or 0x03 Table 6 18 ISO Control Register ISO_4 to ISO_0 iso_4 iso_3 iso_2 iso_1 iso_0 PROTOCOL REMARKS 0 0 0 0 0 ISO IEC 15693 low bit rate 6 62 kbps one subcarrier 1 out of 4...

Страница 48: ...SOF 1 length 02 etu B2 sof_l0 1 SOF 0 length 11 etu 0 SOF 0 length 10 etu B1 l_egt 1 EGT after each byte 0 EGT after last byte is omitted B0 Unused 6 14 1 2 2 ISO14443A High Bit Rate and Parity Option...

Страница 49: ...imer length MSB See Table 6 22 for timer length description B4 tm_lengthC Timer length B3 tm_lengthB Timer length B2 tm_lengthA Timer length B1 tm_length9 Timer length B0 tm_length8 Timer length LSB 6...

Страница 50: ...at 212 kbps 737 ns for ISO IEC 14443 A at 424 kbps 442 ns for ISO IEC 14443 A at 848 kbps pulse length control disabled B6 Pul_p1 B5 Pul_p0 B4 Pul_c4 B3 Pul_c3 B2 Pul_c2 B1 Pul_c1 B0 Pul_c0 6 14 1 2...

Страница 51: ...t operation in which the receive decoders are not active held in reset state This prevents incorrect detections resulting from transients following the transmit operation The value of the RX wait time...

Страница 52: ...OOK or ASK using the OOK pin is only possible if the function is enabled by setting B6 1 en_ook_p in this register 0x09 and the ISO Control register 0x01 B6 1 When configured this way the MOD pin pin...

Страница 53: ...UNCTION DESCRIPTION B7 C212 Band pass 110 kHz to 570 kHz Appropriate for 212 kHz subcarrier system FeliCa B6 C424 Band pass 200 kHz to 900 kHz B5 M848 Band pass 450 kHz to 1 5 MHz Appropriate for Manc...

Страница 54: ...pin becomes modulation output for external TX amplifier B5 io_low 1 Enable low peripheral communication voltage When B5 1 maintains the output driving capabilities of the I O pins connected to the le...

Страница 55: ...V VDD_A 2 9 V VDD_X 2 9 V 0B 0 0 0 1 VDD_RF 2 8 V VDD_A 2 8 V VDD_X 2 8 V 0B 0 0 0 0 VDD_RF 2 7 V VDD_A 2 7 V VDD_X 2 7 V 1 x don t care Table 6 31 Supply Regulator Setting Automatic 5 V System REGIS...

Страница 56: ...nd of TX Signals that TX is in progress The flag is set at the start of TX but the interrupt request IRQ 1 is sent when TX is finished B6 Irg_srx IRQ set due to RX start Signals that RX SOF was receiv...

Страница 57: ...pt enable for FIFO Default 1 B4 En_irq_err1 Interrupt enable for CRC Default 1 B3 En_irq_err2 Interrupt enable for Parity Default 1 B2 En_irq_err3 Interrupt enable for Framing error or EOF Default 1 B...

Страница 58: ...reader so the new tag response level can be measured Section 6 7 1 1 and Section 6 7 1 2 describe the RSSI levels calculated to RF_IN1 and RF_IN2 The RSSI has 7 steps 3 bits with 4 dB increment The in...

Страница 59: ...output selection 0 First stage output used for analog out and digitizing 1 Second stage output used for analog out and digitizing B3 low2 Second stage gain 6 dB HP corner frequency 2 B2 low1 First sta...

Страница 60: ...Fb3 FIFO bytes fb 3 Bits B0 B3 indicate how many bytes that are loaded in FIFO were not read out yet displays N 1 number of bytes If 8 bytes are in the FIFO this number is 7 also see register 0x0C bi...

Страница 61: ...nd EN 0 The register is also automatically reset at TX EOF Table 6 41 TX Length Byte2 Register 0x1E BIT NO BIT NAME FUNCTION DESCRIPTION B7 Txl3 Number of complete byte bn 3 Low nibble of complete int...

Страница 62: ...are essential to avoid interference The recommended clock frequency on the DATA_CLK line is 2 MHz This schematic shows matching to a 50 port which allows connection to a properly matched 50 antenna c...

Страница 63: ...s Avoid crossing of digital lines under RF signal lines Also avoid crossing of digital lines with other digital lines whenever possible If the crossings are unavoidable 90 crossings should be used to...

Страница 64: ...mpedance Matching Smith Chart Resulting power out can be measured with a power meter spectrum analyzer with power meter function or other equipment capable of making a hot measurement Take care to obs...

Страница 65: ...ly qualified production devices with no prefix Device development evolutionary flow xTRF Experimental device that is not necessarily representative of the electrical specifications of the final device...

Страница 66: ...entire system current draw over time is of the utmost concern TRF7960A RFID Multiplexer Example System This application report describes the 16 channel high frequency HF 13 56 MHz RFID reader system...

Страница 67: ...tric changes could cause the device not to meet its published specifications 8 8 Export Control Notice Recipient agrees to not knowingly export or re export directly or indirectly any product or techn...

Страница 68: ...exas Instruments Incorporated 9 Mechanical Packaging and Orderable Information The following pages include mechanical packaging and orderable information This information is the most current data avai...

Страница 69: ...000ppm threshold Antimony trioxide based flame retardants must also meet the 1000ppm threshold requirement 3 MSL Peak Temp The Moisture Sensitivity Level rating according to the JEDEC industry standar...

Страница 70: ...PACKAGE OPTION ADDENDUM www ti com 10 Dec 2020 Addendum Page 2...

Страница 71: ...Pins SPQ Reel Diameter mm Reel Width W1 mm A0 mm B0 mm K0 mm P1 mm W mm Pin1 Quadrant TRF7960ARHBR VQFN RHB 32 3000 330 0 12 4 5 3 5 3 1 5 8 0 12 0 Q2 TRF7960ARHBT VQFN RHB 32 250 180 0 12 4 5 3 5 3 1...

Страница 72: ...Package Type Package Drawing Pins SPQ Length mm Width mm Height mm TRF7960ARHBR VQFN RHB 32 3000 853 0 449 0 35 0 TRF7960ARHBT VQFN RHB 32 250 210 0 185 0 35 0 PACKAGE MATERIALS INFORMATION www ti com...

Страница 73: ...IEW Images above are just a representation of the package family actual package may vary Refer to the product data sheet for package details VQFN 1 mm max height RHB 32 PLASTIC QUAD FLATPACK NO LEAD 5...

Страница 74: ...2 25 OPTIONAL PIN 1 ID 0 1 C A B 0 05 C EXPOSED THERMAL PAD 33 SYMM SYMM NOTES 1 All linear dimensions are in millimeters Any dimensions in parenthesis are for reference only Dimensioning and toleranc...

Страница 75: ...age is designed to be soldered to a thermal pad on the board For more information see Texas Instruments literature number SLUA271 www ti com lit slua271 5 Vias are optional depending on application re...

Страница 76: ...4223442 B 08 2019 NOTES continued 6 Laser cutting apertures with trapezoidal walls and rounded corners may offer better paste release IPC 7525 may have alternate design recommendations 33 SYMM METAL...

Страница 77: ...e resources are subject to change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reprod...

Отзывы: