Test Point Descriptions
www.ti.com
6
SLVU580C – November 2011 – Revised January 2017
Submit Documentation Feedback
Copyright © 2011–2017, Texas Instruments Incorporated
TPS65217 EVM
5
Test Point Descriptions
(1)
Test points are not designed to carry current. They are intended for measuring voltage.
(2)
The test points for high current nodes (BAT, AC, USB, DCDC1, DCDC2, and DCDC3) are designed to
measure voltage at their respective input/output capacitor.
Table 2. Test Points
(1) (2)
Test Point
Description
BAT
Battery
AC
AC adapter input
USB
USB voltage input
nWAKEUP
Wakeup output signal
MUXI
Input to analog multiplexer
MUXO
Output of analog multiplexer
DCDC1
DCDC1 output voltage
GND
Ground
DCDC2
DCDC2 output voltage
GND
Ground
PGOOD
Power Good
SDA
I2C Data
SCL
I2C Clock
DCDC3
DCDC3 output voltage
nINT
Interrupt Output
GND
Ground
GND
Ground
LDOPG
LDO Power Good
6
Jumper Descriptions
Table 3. Jumpers
Jumper
Description
JP6
Connects battery to battery voltage sense input. User should only install this jumper if use of the battery charger is
desired and the supply connected to BAT is capable of sinking current.
JP9
Used to pull PWREN either high or low. If not installed, the software can control PWR_EN via the GPIO_PWR_EN
signal.
JP11
Connects TS input to a 10k resistor to simulate a thermistor. If using a battery pack, do not install this jumper. Instead,
use J4 to connect thermistor to TS.
JP18
Connects VIO to 3P3. Do not install if other VIO supply is desired.
JP39
Allows user to select input to LS1
JP42
Allows user to select input to LS2
ISINK1
Connects LED string to ISINK1. Must connect to use LEDs.
ISINK2