3 Test Procedure
Use the following steps for the test procedure:
1. Set the power supply current limit to 10 A. Set the power supply to something around 12 V. Turn off the power
supply. Connect the positive output of the power supply to J1 and the negative output to J2.
2. Connect the load to J3 for the positive connection and J4 for the negative connection.
3. Turn on the power supply.
4. Slowly increase the load while monitoring the output voltage between J3 and J4. It must remain in regulation
when the load current is lower than 3 A.
5. Slowly sweep the input voltage from 5 V to 20 V. The output voltage must remain in regulation when the load
current is lower than the maximum load current specified in
.
6. Turn off the load, turn off the power supply. Then turn on the load to discharge the output capacitors.
4 Schematic, Bill of Materials, and Board Layout
This section provides the TPS552882EVM-2MHz schematic, bill of materials (BOM), and board layout.
Test Procedure
SLVUBW5A – JUNE 2020 – REVISED OCTOBER 2020
TPS552882EVM-2MHz Evaluation Module
3
Copyright © 2020 Texas Instruments Incorporated