22uF
C6_P2
1µF
C10_P2
DNP
22uF
C5_P2
10
R3_P2
6800pF
C7_P2
6800pF
C8_P2
22uF
C3_P2
100uF
C2_P2
22uF
C4_P2
6800pF
C9_P2
0
R15_P2
0.1uF
C16_P2
DNP
4.7uF
C15_P2
7.50k
R14_P2
0.1uF
C20_P2
EN
AVIN
PVIN
PVIN
2.2µF
C18_P2
DNP
10.0k
R26_P2
PG
ADRSEL
VSEL
MSEL1
MSEL2
ADRSEL
SNS+
SMBALT
PM_CLK
PM_DAT
BC_CLK
BC_DAT
VIN
GND
SNS-
SW
VSH
GND
GND
VDD5
GND
BP1V5
BP1V5
VDD5
AGND
GND
AGND
30.1k
R9_P2
0
R27_P2
0
R25_P2
0
R23_P2
0
R16_P2
0
R22_P2
SYNC
1000pF
C12_P2
1.0
R6_P2
GND
49.9
R5_P2
1
2
SMB1_P2
TP2_P2
TP4_P2
TP5_P2
45V
D1_P2
0.1uF
C13_P2
0
R4_P2
0
R1_P2
DNP
VDD5
CNTL
100pF
C17_P2
DNP
EN
GND
CNTL Jumper
1µF
C14_P2
DNP
1µF
C11_P2
S_VIN
NT1_P2
Net-Tie
VDD5
EXT_5V
1
2
3
4
5
6
JP2_P2
1
2
JP1_P2
TP1_P2
TP3_P2
PG_S
BP1V5
33pF
C21_P2
AGND
10.0k
R8_P2
AGND
AGND
0
R17_P2
0
R24_P2
DNP
GND
10.5k
R10_P2
DNP
MSEL2
10.5k
R11_P2
DNP
VSEL
10.5k
R20_P2
DNP
10.5k
R12_P2
DNP
53.6k
R13_P2
DNP
MSEL1
2.2µF
C19_P2
DRTN
1µF
C1_P2
GND
DRTN
10
R2_P2
1
2
3
JP7_P2
TP34_P2
DNP
TP35_P2
DNP
14.7k
R19_P2
DNP
12.1k
R21_P2
DNP
0
R18_P2
PGD/RST
1
PMB_DATA
2
PMB_CLK
3
BP1V5
4
DRTN
5
SMB_ALRT
6
BOOT
7
SW
8
SW
9
SW
10
SW
11
SW
12
PGND
13
PGND
14
PGND
15
PGND
16
PGND
17
PGND
18
PGND
19
PGND
20
PVIN
21
PVIN
22
PVIN
23
PVIN
24
PVIN
25
AVIN
26
EN/UVLO
27
VDD5
28
MSEL2
29
VSEL
30
ADRSEL
31
MSEL1
32
VOSNS
33
GOSNS/FLWR
34
VSHARE
35
NC
36
AGND
37
SYNC
38
BCX_CLK
39
BCX_DAT
40
PAD
41
TPS546B24ARVFR
U1_P2
Figure 3-3. TPS546B24AEVM-2PH Schematic Page 3 (U1_P2 Loop Follower)
Schematic
8
TPS546B24A 2-Phase SWIFT™ Step-Down Converter Evaluation Module User's Guide
SLUUC48A – FEBRUARY 2020 – REVISED FEBRUARY 2022
Copyright © 2022 Texas Instruments Incorporated