3.12 Thermal Performance
show the temperature rise of the TPS543320 ICs at full 3-A load.
have only one TPS543320 on and loaded.
and
have both TPS543320s
loaded. A minimum of a 10 minute soak time was used before taking each measurement.
Figure 3-34. U1 Thermal Performance – 3-A Load
and U2 off
Figure 3-35. U2 Thermal Performance – 3-A Load
and U1 off
Figure 3-36. U1 Thermal Performance – Both 3-A
Load
Figure 3-37. U2 Thermal Performance – Both 3-A
Load
Test Setup and Results
SLVUC07A – DECEMBER 2020 – REVISED MAY 2021
TPS543320 SWIFT™ Step-Down Converter Evaluation Module User's Guide
23