Mechanical Data and Layout Considerations
22
SLVA075
6.2
Layout Considerations
The following four points should be followed at the layout to ensure trouble-free
operation:
•
Use a blocking capacitor of 100 nF between supply voltage and ground.
•
Place the external capacitor near the device.
•
If the circuit includes a device with a high current consumption, keep the
common ground wire small due to the danger of a floating ground. This can
be achieved by keeping the ground line separated as long as possible
(star-shape connection).
•
Locate the supervisor circuit in an interference-free environment.
The following two figures show layouts with the TPS3801 and TPS3809. The
used capacitor is in a 0805-package ( L x W x H : 2 mm 1.25 mm 0.45 mm).
GND
GND
RESET
MR
C
1 mm
V
DD
Figure 26. Layout Suggestion Using a
TPS3801
Figure 27. Layout Suggestion Using a
TPS3809
GND
RESET
C
1 mm
V
DD