Voltage Supervision at the V
DD
Terminal
8
SLVA075
VDD and RESET
VDD and
RESET
RESET
Figure 8. Measurement of the Voltage Drop at V
DD
A delay time of 232 ms is measured. This parameter is specified between 120 ms
minimum value and 280 ms maximum value with a typical value of 200 ms. This
wide range is because of variations in the process. The oscillator is built up
internally with an RC network.
3.3
Threshold Overdrive Versus Pulsewidth
The datasheet specifies, that a voltage drop of 3
µ
s to at least 200 mV below the
negative-going threshold voltage V
IT–
must trigger a reset pulse. But what
happens with a shorter, but deeper drop? This question is answered with the
measurements shown in Figure 9 and Figure 10.
The x-axis shows the duration of the voltage drop, the y-axis shows the
breakdown voltage of the drop down from 5 V respectively 2.5 V.
Содержание TPS3801
Страница 28: ...24 SLVA075 ...