1
SLVUAV3A – August 2016 – Revised February 2017
Copyright © 2016–2017, Texas Instruments Incorporated
TPS26600-02EVM: Evaluation Module for TPS2660x
User's Guide
SLVUAV3A – August 2016 – Revised February 2017
TPS26600-02EVM: Evaluation Module for TPS2660x
This user’s guide describes the evaluation module (EVM) for the Texas instruments TPS26600,
TPS26601, and TPS26602 devices. The document provides configuration information and test setup
details for working with the EVM. The EVM schematic, board layout and bill of materials (BOM) are also
included.
NOTE:
The TPS26602 can be evaluated on this EVM by replacing the TPS26600PWP (U1) or
TPS26600RHF (U2) with the TPS26602PWP or TPS26602RHF, on respective channels.
Instructions for evaluation are listed in
. The TPS26601 can be evaluated on
this EVM by replacing the TPS26600RHF (U2) with the TPS26601RHF. Instructions for
evaluation are listed in
Contents
1
Introduction
...................................................................................................................
2
Description
....................................................................................................................
3
Schematics
...................................................................................................................
4
General Configurations
.....................................................................................................
5
EVM Board Assembly Drawings and Layout Guidelines
.............................................................
6
Bill Of Materials (BOM)
....................................................................................................
List of Figures
1
TPS26600-02EVM Schematic
.............................................................................................
2
EVM Test Setup
.............................................................................................................
3
Output Voltage Start-Up Waveform
......................................................................................
4
J5/J12 = 2-3 Position, Current Limit (2.23 A), Auto-Retry Mode
.....................................................
5
J5/J12 = 1-2 Position, Current Limit (2.23 A), Latch-Off Mode
......................................................
6
Restart From Latch-Off Mode
............................................................................................
7
J5/J12 = Floating, Current Limit (2.23 A), Circuit Breaker With Auto-Retry Mode
................................
8
Output Short-Circuit Protection
...........................................................................................
9
Reverse Polarity Protection
...............................................................................................
10
Top Side Placement
.......................................................................................................
11
Top Layer
...................................................................................................................
12
Bottom Layer
................................................................................................................
List of Tables
1
TPS26600-02EVM Options and Setting
..................................................................................
2
Input and Output Connector Functionality
................................................................................
3
Test Points Description
.....................................................................................................
4
Jumper and LED Descriptions
.............................................................................................
5
Power Supply Setting for the TPS26600-02EVM
........................................................................
6
Default Jumper Setting for the TPS26600-02EVM
......................................................................
7
TPS26600-02EVM DMM Readings at Different Test Points
...........................................................
8
TPS26600-02EVM Oscilloscope Setting for the Output Voltage Start-Up Test
.....................................
9
TPS26600-02EVM Oscilloscope Setting for the Current Limit Test
..................................................