5 EVM Setup
The following instructions are for setting up the EVM:
1. If you desire to use this EVM with all channels loaded, then solder down your chosen 0805 components to
the channels you wish to test.
describes which loads correspond to what pin on the TMUX646.
Table 5-1. Configurable Load Matrix
Pin Name
0805 Resistor Pad ID (SE)
0805 Capacitor Pad ID (D)
0805 Resistor Pad ID (D)
D1P
R12
C4
R10
D1N
R11
C4
R10
D2P
R9
C3
R7
D2N
R8
C3
R7
D3P
R6
C2
R4
D3N
R5
C2
R4
D4P
R3
C1
R1
D4N
R2
C1
R1
CLKP
R14
C5
R13
CLKN
R15
C5
R13
DA1P
R21
C7
R19
DA1N
R20
C7
R19
DA2P
R24
C8
R22
DA2N
R23
C8
R22
DA3P
R27
C9
R25
DA3N
R26
C9
R25
DA4P
R30
C10
R28
DA4N
R29
C10
R28
CLKAP
R17
C6
R16
CLKAN
R18
C6
R16
DB1P
R36
C12
R34
DB1N
R35
C12
R34
DB2P
R39
C13
R37
DB2N
R38
C13
R37
DB3P
R42
C14
R40
DB3N
R41
C14
R40
DB4P
R45
C15
R43
DB4N
R44
C15
R43
CLKBP
R33
C11
R31
CLKBN
R32
C11
R31
EVM Setup
6
TMUX646EVM User's Guide
SCDU025 – MAY 2021
Copyright © 2021 Texas Instruments Incorporated