2.3
Electrical Characteristics Over Recommended Ranges of Supply Voltage
and Operating Free-Air Temperature (unless otherwise noted)
2.3.1
Signal Interface
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VOL
Low-level output voltage, OUT
IOL < 5 mA
0.5
V
VOL
Low-level output voltage, OSCC
0.6
0.7
V
VOH
High-level output voltage, OUT
IOH < 5 mA
VCC – 0.5
V
VOH
High-level output voltage, OSCC
1.2
1.6
V
II
Input current, IN
VI = 0 V to 6 V
±
10
µ
A
IO
Output current, OUT
VO = 0 V to 12 V
±
10
µ
A
Ci
Input capacitance
10
pF
Co
Output capacitance
5
pF
2.3.2
Amplifier
PARAMETER
TEST CONDITIONS
MIN
TYP
MAX
UNIT
VI(PP)
Peak-to-peak input voltage
3
mV
VN(PP) External peak-to-peak noise voltage
1
mV
VO
Output voltage, TIME
VOL
VOH
V
VI = 3 mV
15
B
Bandwidth
VI = 100 mVpeak to peak
500
kHz
VI = 200 mVpeak to peak
1000
AV
Flatband gain
CEX (nF) > 900/fosc (kHz)
200
V/V
AV
Flatband gain
CEX not connected
1
V/V
2.3.3
Internal Oscillator (see Note 3)
PARAMETER
MIN
TYP
MAX
UNIT
fRX
Receiver frequency
10
500
kHz
fTX
Transmitter frequency
fRX/10
fRX/10
fRX/5.5
kHz
Frequency spread (temperature, VCC)
±
20%
NOTE 3: Typical values are recommended whenever possible.
2.3.4
Power-On Reset
PARAMETER
MIN
MAX
UNIT
VCC level required to trigger power-on reset
2.7
V
Power-on reset duration
40
ms
2.3.5
Write/Erase Endurance
PARAMETER
MIN
TYP
MAX
UNIT
Number of program cycles
20
10 000