Functional Unit Constraints
Pipeline
4-40
SPRU733
4.3.2 .M-Unit Constraints
Table 4
−
24 shows the instruction constraints for 16
×
16 multiply instructions
executing on the .M unit.
Table 4
−
24. 16
16 Multiply .M-Unit Instruction Constraints
Instruction Execution
Cycle
1
2
3
16
×
16 multiply
R
W
Instruction Type
Subsequent Same-Unit Instruction Executable
16
×
16 multiply
4-cycle
MPYI
MPYID
MPYDP
Instruction Type
Same Side, Different Unit, Both Using Cross Path Executable
Single-cycle
Load
Store
DP compare
2-cycle DP
Branch
4-cycle
INTDP
ADDDP/SUBDP
Legend:
= E1 phase of the single-cycle instruction; R = Sources read for the instruction; W = Destinations written for the
instruction;
= Next instruction can enter E1 during cycle