17.5.43 USB Request Packet Count in Block Transfer Endpoint n Registers (USBRQPKTCOUNT[1]-
USBRQPKTCOUNT[3)
The USB receive packet count in block transfer endpoint
n
16-bit read/writer registers are used in Host mode
to specify the number of packets that are to be transferred in a block transfer of one or more bulk packets
to receive endpoint
n
. The USB controller uses the value recorded in this register to determine the number of
requests to issue where the AUTORQ bit in the USBRXCSRH[
n
] register has been set. For more information
about IN transactions as a host, see
Note:
Multiple packets combined into a single bulk packet within the FIFO count as one packet.
For the specific offset for each register, see
Mode(s):
Host
The USBRQPKTCOUNT[
n
] registers are shown in
.
Figure 17-55. USB Request Packet Count in Block Transfer Endpoint n Registers (USBRQPKTCOUNT[n])
15
13
12
0
Reserved
COUNT
R-0
R-0
LEGEND: R/W = Read/Write; R = Read only; -
n
= value after reset
Table 17-58. USB Request Packet Count in Block Transfer Endpoint n Registers (USBRQPKTCOUNT[n])
Field Descriptions
Bit
Field
Value
Description
15-13
Reserved
0
Reserved
12-0
COUNT
Block Transfer Packet Count sets the number of packets of the size defined by the MAXLOAD bit field
that are to be transferred in a block transfer.
Note:
This is only used in Host mode when AUTORQ is set. The bit has no effect in Device mode or
when AUTORQ is not set.
Universal Serial Bus (USB) Controller
SPRUH18I – JANUARY 2011 – REVISED JUNE 2022
TMS320x2806x Microcontrollers
1125
Copyright © 2022 Texas Instruments Incorporated
Содержание TMS320 2806 Series