HARMONIC
α
i
β
i
1
–7.3
0.35
2
1.17
0.22
3
–2.23
0.28
4
–0.81
–0.14
5
–0.075
0.01
6
–0.035
0.02
7
–0.03
–0.005
8
–0.01
0
DRV5055 Off-Axis Calibrated Angle Error
shows the resulting error after applying the harmonic data.
Figure 3-23. DRV5055 Off-Axis Calibrated Angle Error
Hardware, Software, Testing Requirements, and Test Results
Absolute Angle Encoder Reference Design With Hall-Effect Sensors for
Precise Motor Position Control
31
Copyright © 2022 Texas Instruments Incorporated