Multi-Channel Setup
6
SLOU495 – December 2017
Copyright © 2017, Texas Instruments Incorporated
TAS2770 Evaluation Module
ECCN: 3E991
6
Multi-Channel Setup
Use the following for multi-channel setup:
1. Install PurePath Console 3 with the TAS2770EVM plug-in.
2. Connect up to 8 TAS2770 EVMs together using connectors J5 and J7.
3. Attach a power supply to each board.
4. The leftmost board should have jumpers set to match the mono configuration. On all other boards,
insert a jumper on J2 and J6. PPC3 will recognize 1, 2, 4, or 8 channel setups. See
for
details.
5. Set Jumper J13 on each board to a unique address.
6. Verify that the EVM is the default playback device by opening the sound dialog from the
Windows
Control Panel
as shown in
7. Set the sampling rate using the Windows setting by opening Properties > Advanced. The
TAS2770EVM supports 44.1-kHz and 48-kHz sampling rates.
8. Set the bit depth as desired using the
Texas Instruments USB Audio Control Panel
accessible from the
system tray shown in
.
9. Configure the device using PPC3.
10. Connect the leftmost EVM to a Windows 7+ PC with a micro-USB cable (J16).
Figure 4. Multi-Channel Setup