background image

Important Notice for Users of this Product in Japan

This development kit is NOT certified as Confirming to Technical Regulations of Radio Law of Japan

If you use this product in Japan, you are required by Radio Law of Japan to follow the instructions below with respect to this product:

1.

Use this product in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal Affairs and
Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for Enforcement of Radio Law of
Japan,

2.

Use this product only after you obtained the license of Test Radio Station as provided in Radio Law of Japan with respect to this
product, or

3.

Use of this product only after you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with
respect to this product. Also, please do not transfer this product, unless you give the same notice above to the transferee. Please note
that if you could not follow the instructions above, you will be subject to penalties of Radio Law of Japan.

Texas Instruments Japan Limited

(address) 24-1, Nishi-Shinjuku 6 chome, Shinjuku-ku, Tokyo, Japan

http://www.tij.co.jp

【ご使用にあたっての注】

本開発キットは技術基準適合証明を受けておりません。

本製品のご使用に際しては、電波法遵守のため、以下のいずれかの措置を取っていただく必要がありますのでご注意ください。

1.

電波法施行規則第

6

条第

1

項第

1

号に基づく平成

18

3

28

日総務省告示第

173

号で定められた電波暗室等の試験設備でご使用いただく。

2.

実験局の免許を取得後ご使用いただく。

3.

技術基準適合証明を取得後ご使用いただく。

なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。

   上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。

日本テキサス・インスツルメンツ株式会社

東京都新宿区西新宿6丁目24番1号

西新宿三井ビル

http://www.tij.co.jp

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

SPACER

Содержание SN74AVC2T244EVM

Страница 1: ...signed to track VCCB VCCB accepts any supply voltage from 0 9 V to 3 6 V This allows for low voltage bidirectional translation between 1 V 1 2 V 1 5 V 1 8 V 2 5 V and 3 3 V voltage nodes The SN74AVC2T244 EVM was created to allow simplified evaluation and prototyping without the need for full board development This EVM provides peripheral header style pads for probing and signal connection to each ...

Страница 2: ... connection length and keep GND leads short when probing This will ensure minimal capacitive resistive and inductive loading caused by the connection and connector For more device information please see the SN74AVC2T244 device datasheet or visit the TI support forums e2e ti com 4 PCB Layout Figure 1 Top Layer 2 SN74AVC2T244 Evaluation Module SCEU002 September 2011 Submit Documentation Feedback Cop...

Страница 3: ...ww ti com PCB Layout Figure 2 Bottom Layer Figure 3 Assembly Top Layer 3 SCEU002 September 2011 SN74AVC2T244 Evaluation Module Submit Documentation Feedback Copyright 2011 Texas Instruments Incorporated ...

Страница 4: ... 4 1 1 1 1 PCB Layout www ti com Figure 4 Assembly Bottom Layer Figure 5 Composite 4 SN74AVC2T244 Evaluation Module SCEU002 September 2011 Submit Documentation Feedback Copyright 2011 Texas Instruments Incorporated ...

Страница 5: ... 2 3 4 J1 1 2 3 4 J2 J3 J4 J5 1 VCCA 2 A1 3 A2 4 OE 5 GND 6 B2 7 B1 8 VCCB U1 SN74AVC2T244DQM J6 www ti com SN74AVC2T244 EVM Schematic 5 SN74AVC2T244 EVM Schematic 5 SCEU002 September 2011 SN74AVC2T244 Evaluation Module Submit Documentation Feedback Copyright 2011 Texas Instruments Incorporated ...

Страница 6: ...uct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer or visit www ti com esh No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine process or combination in which such TI products or...

Страница 7: ...ency energy and has not been tested for compliance with the limits of computing devices pursuant to part 15 of FCC or ICES 003 rules which are designed to provide reasonable protection against radio frequency interference Operation of the equipment may cause interference with radio communications in which case the user at his own expense will be required to take whatever measures may be required t...

Страница 8: ... its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication This radio transmitter has been approved by Industry Canada to operate with the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this l...

Страница 9: ...er you obtained the Technical Regulations Conformity Certification as provided in Radio Law of Japan with respect to this product Also please do not transfer this product unless you give the same notice above to the transferee Please note that if you could not follow the instructions above you will be subject to penalties of Radio Law of Japan Texas Instruments Japan Limited address 24 1 Nishi Shi...

Страница 10: ... property damage personal injury or death If there are questions concerning these ratings please contact a TI field representative prior to connecting interface electronics including input power and intended loads Any loads applied outside of the specified output range may result in unintended and or inaccurate operation and or possible permanent damage to the EVM and or interface electronics Plea...

Страница 11: ...regulatory and safety related requirements concerning its products and any use of TI components in its applications notwithstanding any applications related information or support that may be provided by TI Buyer represents and agrees that it has all the necessary expertise to create and implement safeguards which anticipate dangerous consequences of failures monitor failures and their consequence...

Отзывы: