Testing the PGA5807A EVM
Figure 44. PGA5807 GUI Setup for PG ADS5296A 1
3. Click on the
ADC
tab and press
Capture
to see result similar to
. Take note of the
Fund.
value in the table to the left. In a similar manner to that described in
, the input signal
amplitude to the PGA5807A should be adjusted and a re-capture done iteratively until the
Fund.
value
is approximately –1.0 dBFs. As –1.0 dBFs is the ADC level at which datasheet specifications are set,
the
SNR
and
THD
of the signal chain can be taken from the table to left at this value of
Fund.
Figure 45. PG ADS5296A SNR, THD, Gain Test Capture 1
33
SLAU538 – October 2013
PGA5807A, 8-Channel, High-Bandwidth, Analog Front-End Evaluation
Module
Copyright © 2013, Texas Instruments Incorporated