Software
34
SLDU031 – December 2017
Copyright © 2017, Texas Instruments Incorporated
PGAxxxEVM-037 Pressure Sensor Signal Conditioner Evaluation Module
Table 6. Fault Status Indicators (continued)
Fault Indicator
Description
OWI Invalid CMD
OWI command field invalid. See device datasheet for available OWI commands
VBRG_OV
Bridge Supply OV Flag; Bridge Supply voltage > 1.15 times nominal value
VBRG_UV
Bridge Supply UV Flag; Bridge Supply voltage < 0.85 times nominal value
REF_OV
Reference OV Flag; Reference voltage > 1.1 times nominal value
REF_UV
Reference UV Flag; Reference voltage > 0.9 times nominal value
DVDD_OV
DVDD OV Flag; DVDD voltage > 1.15 times nominal value
DVDD_UV
DVDD UV Flag; DVDD voltage < 0.9 times nominal value
VINP_OV
Overvoltage on VINPP or VINPN pins
VINP_UV
Undervoltage on VINPP or VINPN pins
VINT_OV
Overvoltage on VINTP or VINTN pins
VINT_UV
Undervoltage on VINTP or VINTN pins
PGAIN_OV
Overvoltage at PGAIN output
PGAIN_UV
Undervoltage at PGAIN output
TGAIN_OV
Overvoltage at TGAIN output
TGAIN_UV
Undervoltage at TGAIN output
4.15.5
Resistive Bridge Configuration Panel
Figure 26. Resistive Bridge Configuration Panel
The
Resistive Bridge Configuration
panel allows the user to control the digital potentiometer that makes up
one leg of the resistive bridge emulator on the EVM. This can be used to generate a differential voltage
across the VINTP and VINTN or the VINPP and VINPN pins depending on the jumper configuration. The
drop-down box allows the user to select a resistance in k
Ω
; the resulting change in the Vp voltage as well
as the differential voltage of Vp – Vn are automatically updated in the schematic.