background image

www.ti.com

Safety

7

SBOU156B – October 2015 – Revised February 2017

Submit Documentation Feedback

Copyright © 2015–2017, Texas Instruments Incorporated

OPT8241 Evaluation Module

3

Safety

This Laser Device is designed at Class 1 during normal operation. While the OPT8241-CDK-EVM
development boards meet the Class 1 classification requirements under EN/IEC60825-1 2007, users are
advised to take the necessary safety caution when using the OPT8241-CDK-EVM. First, examine the
board for any damage before the board is powered. Check that the diffusers and diffuser mounts are
properly secured on the laser diodes. If there is any damage, stop operating by removing power from the
CDK immediately. Opening the laser diffuser assembly may lead to hazardous radiation exposure. Any
kind of circuit modification to the board or use of software or firmware other than the recommended EVM
tools and firmware provided by TI may lead to violation of class 1 safety limits. Due to the small size and
unsuitability for labeling, laser safety related labels are included herein, rather than on the product.

WARNING

Use of controls or adjustments or performance of procedures other
than those specified herein may result in hazardous radiation
exposure.

This is a class A product as defined by standard EN 61326-1:2013. This product is not intended to be
used in domestic establishments and also in establishments that are directly connected to a low-voltage
power-supply network that supplies buildings used for domestic purposes. In a domestic environment this
product may cause radio interference in which case the user may be required to take adequate measures.

There is no scheduled maintenance required for the OPT8241-CDK-EVM; any servicing and maintenance
of this EVM shall be performed only by trained Texas Instruments or TI-appointed trained personnel. Any
modification or significant damage to the CDK could potentially cause the CDK to operate outside of the
EN/IEC60825 2007 Class 1 classification limits.

Figure 2. Explanatory Label

For reference and future support, user should keep a record of the revision and serial number by entering
the information in the following location:

Figure 3. Manufacturer Label

Содержание OPT8241-CDK-EVM

Страница 1: ...OPT8241 CDK Evaluation Module Quick Start Guide Literature Number SBOU156B October 2015 Revised February 2017...

Страница 2: ...Contents Contents 1 Overview 5 2 CDK Contents 5 3 Safety 7 4 Power Supply 9 5 Top Level Specifications Of The EVM 9 6 System Requirements 9 7 Software Setup 10 8 Hardware Setup 10 9 Launching the Soft...

Страница 3: ...nstruments Incorporated List of Figures List of Figures 1 Components of EVM 5 2 Explanatory Label 7 3 Manufacturer Label 7 4 Serial Numbers 8 5 Certification Label 8 6 Hot To Touch 8 7 Streaming Enabl...

Страница 4: ...egistered trademark of Linus Torvalds Microsoft Windows are registered trademarks of Microsoft Corporation All other trademarks are the property of their respective owners Quick Start Guide SBOU156B O...

Страница 5: ...e The EVM showcases the high performance QVGA resolution 3D Time of Flight sensor OPT8241 with its companion Time of Flight Controller OPT9221 Figure 1 highlights the important components of the EVM F...

Страница 6: ...Texas Instruments Incorporated OPT8241 Evaluation Module Table 1 Contents of CDK continued Content Description Number of Pieces Third party brochure Metrilus calibration suite brochure 1 Complies with...

Страница 7: ...labeling laser safety related labels are included herein rather than on the product WARNING Use of controls or adjustments or performance of procedures other than those specified herein may result in...

Страница 8: ...ry 2017 Submit Documentation Feedback Copyright 2015 2017 Texas Instruments Incorporated OPT8241 Evaluation Module The revision and the serial numbers are located on the boards here Figure 4 Serial Nu...

Страница 9: ...pecifications Of The EVM The top level specifications of the EVM are listed in Table 2 Table 2 EVM Specification Item Value Typical External power supply requirements 3 A at 5 V Pixel resolution 320 2...

Страница 10: ...y is C Program Files Texas Instruments Voxel Viewer 0 x y z on Windows On Ubuntu the name of the executable is voxelviewer 8 Hardware Setup The hardware setup is shown in the following steps 1 Ensure...

Страница 11: ...d automatically start 3 If the EVM is connected after the viewer has started use the camera connection dialog box to refresh the list of cameras choose the appropriate camera and click OK The camera c...

Страница 12: ...l operating conditions the master LED should be green cyan and the chipset LED should be blue 11 Related Documentation from Texas Instruments Related documentation regarding the EVM is available here...

Страница 13: ...set forth above or credit User s account for such EVM TI s liability under this warranty shall be limited to EVMs that are returned during the warranty period to the address designated by TI and that...

Страница 14: ...the antenna types listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated Antenna types not included in this list having a gain greate...

Страница 15: ...t the EVM user guide prior to connecting any load to the EVM output If there is uncertainty as to the load specification please contact a TI field representative During normal operation even with the...

Страница 16: ...OST OF REMOVAL OR REINSTALLATION ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES RETESTING OUTSIDE COMPUTER TIME LABOR COSTS LOSS OF GOODWILL LOSS OF PROFITS LOSS OF SAVINGS LOSS OF...

Страница 17: ...TI Resource NO OTHER LICENSE EXPRESS OR IMPLIED BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD...

Отзывы: