MSP430F41x2
MIXED SIGNAL MICROCONTROLLER
SLAS648E -- APRIL 2009 -- REVISED MARCH 2011
41
POST OFFICE BOX 655303
DALLAS, TEXAS 75265
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (continued)
10-bit ADC, built-in voltage reference
PARAMETER
TEST CONDITIONS
V
CC
MIN
TYP
MAX
UNIT
P iti
b ilt i
f
l
I
VREF+
1 mA, REF2_5V = 0
2.2
V
CC,REF+
Positive built-in reference analog
supply voltage range
I
VREF+
0.5 mA, REF2_5V = 1
2.8
V
V
CC,REF+
supply voltage range
I
VREF+
1 mA, REF2_5V = 1
2.9
V
V
REF+
Positive built-in reference voltage
I
VREF+
I
VREF+
max, REF2_5V = 0
2.2 V/
3 V
1.41
1.5
1.59
V
V
REF+
Positive built in reference voltage
I
VREF+
I
VREF+
max, REF2_5V = 1
3 V
2.35
2.5
2.65
V
I
Ma im m V
load c rrent
2.2 V
0.5
mA
I
LD,VREF+
Maximum V
REF+
load current
3 V
1
mA
V
load reg lation
I
VREF+ =
500
A
100
A,
Analog input voltage V
Ax
0.75 V,
REF2_5V = 0
2.2 V/
3 V
2
LSB
V
REF+
load regulation
I
VREF+ =
500
A
100
A,
Analog input voltage V
Ax
1.25 V,
REF2_5V = 1
3 V
2
LSB
V
REF+
load regulation response
I
VREF+
= 100
A
900
A,
V
0 5 x V
Error of
ADC10SR = 0
3 V
400
ns
V
REF+
load regulation response
time
V
Ax
0.5 x V
REF+,
Error of
conversion result
1 LSB
ADC10SR = 1
3V
2000
ns
C
VREF+
Max. capacitance at pin V
REF+
(see Note 1)
I
VREF+
1 mA,
REFON = 1, REFOUT = 1
2.2 V/
3 V
100
pF
TC
REF+
Temperature coefficient
I
VREF+ =
const. with 0 mA
I
VREF+
1 mA
(see Note 3)
2.2 V/
3 V
100 ppm/
C
t
REFON
Settling time of internal reference
voltage (see Note 2)
I
VREF+ =
0.5 mA, REF2_5V = 0,
REFON = 0
1
3.6 V
30
s
I
VREF+ =
0.5 mA,
REF2 5V = 0,
ADC10SR = 0
2.2 V
1
t
Settling time of reference buffer
REF2_5V = 0,
REFON = 1,
REFBURST = 1
ADC10SR = 1
2.2 V
2.5
s
t
REFBURST
Settling time of reference buffer
(see Note 2)
I
VREF+ =
0.5 mA,
REF2 5V = 1,
ADC10SR = 0
3 V
2
s
REF2_5V = 1,
REFON = 1,
REFBURST = 1
ADC10SR = 1
3 V
4.5
NOTES: 1. The
capacitance
applied
to
the
internal
buffer
operational
amplifier,
if
switched
to
terminal
P6.4/UCB0CLK/UCA0STE/A4/CA6/V
eref+
/V
ref+
(REFOUT = 1), must be limited; the reference buffer may become unstable,
otherwise.
2. The condition is that the error in a conversion started after t
REFON
or t
RefBuf
is less than
0.5 LSB.
3. Calculated using the box method: ((MAX(V
REF
(T)) -- MIN(V
REF
(T))) / MIN(V
REF
(T)) / (T
MAX
-- T
MIN
)
Содержание MSP430F4132IPM
Страница 82: ......