Test Setup
11
SNOU165A – September 2018 – Revised March 2019
Copyright © 2018–2019, Texas Instruments Incorporated
Using the LMG341xEVM-018 half-bridge and LMG34XX-BB-EVM breakout
board EVM
4
Test Setup
4.1
Test Equipment
DC Voltage Source: Capable of supplying the input of the EVM up to 480 V
DC Bias Source: Capable of 12 V output at up to 0.7 A
Function Generator: Capable of 0 V to 5 V square wave output with adjustable duty cycle and frequency in
desired operating range. It is recommended to operate the LMG341xEVM-018 and LMG34XX-BB-EVM
with a switching frequency between 50 kHz to 200 kHz.
Oscilloscope: Capable of at least 200 MHz operation. A 1 GHz or greater oscilloscope and probes with
short ground springs are recommended for accurate measurements.
DC Multimeter(s): Capable of 600 V measurement, suitable for determining operation and efficiency (if
desired).
DC Load: Capable of 600 V operation at up to 8 A in current-mode operation.
Fan: 200 LFM minimum airflow is recommended
4.2
Recommended Test Setup
The LMG341xEVM-018 connects to the LMG34XX-BB-EVM as
shows.
Figure 7. LMG3410EVM-018 Connected with LMG34XX-BB-EVM