Dimensions (mm)
Type
A
B
C
1.3
1.4
3.5
9.5
2.1
2.1
5.5
9.0
2.5
2.5
5.5
9.0
DC Power Plugs
Rated at 12 V, 1 A
Installation
www.ti.com
6.1.1
External Power Supply (Optional)
The base station is delivered to operate with USB power supply (0-
Ω
resistor R34 is assembled). For
longer read range, an external supply can be used. The steps to change to external power supply are:
1. Remove the 0-
Ω
resistor from R34 position.
2. Solder the same resistor on position R35.
3. Use external power supply of 9 V to 15 V at 1 A.
4. Use a DC power plug pin with a 2.5-mm diameter (RS Order No. 486-634 or 455-097) (see
Figure 5
).
Figure 5. DC Power Plug
6.1.2
Base Station USB Driver Installation
1. Install the RFID demo software by running RFID Demo Software-1.0-Setup.exe on the PC. This also
installs the device driver for the base station and the eZ430 USB debugging interface (see
Section 5
).
2. Plug the base station into the USB port.
3. Windows recognizes the new hardware as Texas Instruments MSP-FET430UIF (see
Figure 6
).
Windows should automatically install the drivers for the MSP-FET430UIF as an HID tool.
Figure 6. Windows XP Hardware Recognition
4. Windows recognizes another new hardware driver to be installed called MSP430 Application UART
(see
Figure 7
).
Figure 7. Windows XP Hardware Recognition for MSP430 Application UART
12
eZ430-TMS37157 Development Tool
SLAU281B
–
November 2009
–
Revised March 2010
Submit Documentation Feedback
Copyright
©
2009
–
2010, Texas Instruments Incorporated