Commands
4.3
Commands
4.3.1 HOST_CMD_GET_METER_NAME
Read the 32 byte meter name string as defined by #define METER_NAME in metrology-calibration-
template.h
4.3.1.1
Command Format
HOST_CMD_GET_METER_NAME
Command
Respond
LEN
2
34
Offset
Width
Data
Offset
Width
Data
CMDH
0
U8
0x52
0
U8
0x52
CMDL
1
U8
0x00
1
U8
0x80
2
U8(32)
32-byte meter name
4.3.2 HOST_CMD_GET_METER_VER
Read the four 32-bit version numbers as defined by the following lines in metrology-calibration-template.h.
#define METER_SOFTWARE_VERSION
#define METER_HARDWARE_VERSION
#define METER_METROLOGY_VERSION
#define METER_PROTOCOL_VERSION
4.3.2.1
Command Format
HOST_CMD_GET_METER_VERSION
Command
Respond
LEN
2
18
Offset
Width
Data
Offset
Width
Data
CMDH
0
U8
0x53
0
U8
0x53
CMDL
1
U8
0x00
1
U8
0x80
2
U8(4)
4-byte software version
6
U8(4)
4-byte hardware version
10
U8(4)
4-byte metrology version
14
U8(4)
4-byte protocol version
25
SLAU587 – August 2014
Serial Communication Commands
Copyright © 2014, Texas Instruments Incorporated