Texas Instruments DS560MB410EVM Скачать руководство пользователя страница 14

To generate an EEPROM configuration, first configure the DS560MB410 redriver using the 

High Level Page 

and 

Low Level Page

. Then press 

Update Slot from Device

. This will update the selected EEPROM slot with the 

device configuration. Multiple redrivers can have independent configurations in a single EEPROM hex file. Each 
independent configuration is represented by the 

Slot #

. After updating the slot from the device, the EEPROM hex 

file can be saved by pressing the 

Write to EEPROM Hex

 button.

A hex file can be loaded and modified using the 

EEPROM Page

 as well. This can be done by loading the hex file 

using the 

Load from Hex File

 button. Then, press 

Update Device from Slot

 to update the redriver settings from 

the selected EEPROM hex file. After doing this, modifications can be made using the 

High Level Page

 and 

Low 

Level Page

. After making modifications, press 

Update Slot from Device

 to update the selected EEPROM slot 

with the modified device configuration. The EEPROM hex file can then be saved using the 

Write to EEPROM 

Hex

 button.

Figure 5-11. EEPROM Page

5.6 Eye Height Page

The DS560MB410 eye height monitor is an on-chip tool to help determine the ideal CTLE boost index range 
for NRZ and PAM4 signals. This eye height monitor provides information about the eye height across a range 
of EQ Boost Codes. For each EQ Boost Code, an internal DAC is swept through 64 steps. At each step, the 
number of times the signal crosses the DAC voltage in a given time interval is recorded. This is recorded in 
channel registers 0x22-0x25. The eye openings, shown in white, the on 

Eye Height Page

 correspond to DAC 

voltages where the number of crossings did not change much between consecutive DAC values. From this data, 
an optimum EQ Boost Code is recommended.

SigCon Architect

www.ti.com

14

DS560MB410EVM

SNLU296A – DECEMBER 2022 – REVISED DECEMBER 2022

Submit Document Feedback

Copyright © 2022 Texas Instruments Incorporated

Содержание DS560MB410EVM

Страница 1: ...p 3 4 1 Modes of Programmable Communication 3 4 2 Configuration Overview 3 5 SigCon Architect 4 5 1 Installation 4 5 2 Configuration 6 5 3 High Level Page 9 5 4 Low Level Page 13 5 5 EEPROM Page 13 5...

Страница 2: ...es 22 List of Tables Table 3 1 DS560MB410 Ordering Information 3 Table 4 1 Description of SMBus and EEPROM Connections 3 Table 4 2 Test Point Connections Output Voltage 4 Table 5 1 Device Status Setti...

Страница 3: ...full access to the DS560MB410 status and control settings through the on board USB2ANY ADDR0 J6 and ADDR1 J11 headers are used to set the SMBus target address 2 Controller mode provides access to the...

Страница 4: ...e Component Name Description TP1 GND Common Ground TP2 VDD 2 5 V Input TP5 GND Ground TP3 VDD 3 3 V Input 5 SigCon Architect The SigCon Architect software allows for simple configuration of the DS560M...

Страница 5: ...greement 5 When complete the user will be presented with an Installation completed window shown in Figure 5 3 Press Finish to continue If Run SigCon Architect EVM GUI v3 is selected then SigCon Archit...

Страница 6: ...with the DS560MB410 Figure 5 4 shows how prior to establishing a connection with the DS560MB410 the other profile pages will be unselectable indicated by their gray color SigCon Architect www ti com...

Страница 7: ...n the USB2ANY and the SMBus pins on the DS560MB410 A common ground connection is also required 2 Ensure the DS560MB410 is in SMBus Target mode 3 Select appropriate SMBus address by using the Target Ad...

Страница 8: ...he DS560MB410 profile without connecting a DS560MB410 1 Select the checkbox by Demo Mode in the top right corner of SigCon Architect 2 Click the Apply button to enter Demo Mode SigCon Architect www ti...

Страница 9: ...gh the Low Level Page 5 3 1 Device Status The Device Status tab shows a high level overview of the status of each channel in the DS560MB410 Although a summary of channel settings can be viewed from th...

Страница 10: ...gisters Save To File Opens a window enabling the user to save device register data to their computer This file contains data for all of the device registers Continuous Status Update When checked the r...

Страница 11: ...channel selected by the Channel Select setting Apply to All Channels Applies channel settings to all device channels Power Down Channel Powers down channel that is currently selected by the Channel Se...

Страница 12: ...re 5 9 Crosspoint Switch Tab Table 5 3 Crosspoint Switch Settings and Buttons Seting or Button Name Behavior Update Time Sets the time interval at which the device status is updated Channel Select Thi...

Страница 13: ...umped to by selecting a group from the Block Select menu Figure 5 10 Low Level Page Selecting a register will allow the user to read and write data to the register This can be done by entering hexadec...

Страница 14: ...ress Update Slot from Device to update the selected EEPROM slot with the modified device configuration The EEPROM hex file can then be saved using the Write to EEPROM Hex button Figure 5 11 EEPROM Pag...

Страница 15: ...le Opens a window allowing the user to select a file with register data Once the appropriate file is selected register data from the file will be written to device registers Save To File Opens a windo...

Страница 16: ...n with device Reinstall SigCon Architect It is essential SigCon Architect is closed during any portion of the installation process Oscilloscope s Eye Diagram is not as expected Pattern does not lock o...

Страница 17: ...F 25 V 10 X7R 0603 7 1 C33 47 F GRM32ER71A476KE1 5L CAP CERM 47 F 10 V 10 X7R 1210 8 1 C34 22 F T495C226K010ATE30 0 CAP TA 22 F 10 V 10 0 3 SMD 9 1 C35 10 F GRM21BR61E106KA7 3L CAP CERM 10 F 25 V 10...

Страница 18: ...9 Green SSF LXH305GD TR LED Green SMD 26 1 FB1 60 BK1608HS600 T Ferrite Bead 60 at 100 MHz 0 8 A 0603 27 2 J1 J2 142 0701 201 142 0701 201 Connector TH SMA 28 4 J28 J29 J30 J31 0732520091 0732520091 C...

Страница 19: ...W 102 07 G S 61300211121 Header 100mil 2x1 Gold TH 46 1 Q1 50 V BSS138 MOSFET N CH 50 V 0 22 A SOT 23 47 2 R1 R2 10 0k CRCW040210K0FKED RES 10 0 k 1 0 063 W 0402 48 1 R3 750 RNCP0603FTD750R RES 750 1...

Страница 20: ...63 2 R46 R49 33k CRCW040233K0JNED RES 33 k 5 0 063W 0402 64 1 R47 1 2Meg CRCW06031M20JNEA RES 1 2Meg 5 0 1W 0603 65 1 R48 200 CRCW0603200RFKEA RES 200 1 0 1W 0603 66 1 S1 KSR221GLFS KSR221GLFS Switch...

Страница 21: ...25 000MCB T XO 25 000 MHz 2 5V SMD 78 1 Y2 ECS 240 20 5PX TR ECS 240 20 5PX TR Crystal 24 000 MHz 20 pF SMD 79 9 Shunts STC02SYAN STC02SYAN Shunt Placement J15 1 2 3 4 J24 1 2 3 4 J12 5 6 J13 9 10 J16...

Страница 22: ...formance is very good and more than adequate for 25 Gbps operation 2 84099607 MF53 1x8A_21MXP 11SK 305 MXP 40 cable assembly This cable assembly is designed specifically for 40 GHz It features a male...

Страница 23: ...the current version Changes from Revision December 2022 to Revision A December 2022 Page First public release of EVM user s guide 3 www ti com Revision History SNLU296A DECEMBER 2022 REVISED DECEMBER...

Страница 24: ...ther than TI b the nonconformity resulted from User s design specifications or instructions for such EVMs or improper system design or c User has not paid on time Testing and other quality control tec...

Страница 25: ...These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not in...

Страница 26: ...instructions set forth by Radio Law of Japan which includes but is not limited to the instructions below with respect to EVMs which for the avoidance of doubt are stated strictly for convenience and s...

Страница 27: ...any interfaces electronic and or mechanical between the EVM and any human body are designed with suitable isolation and means to safely limit accessible leakage currents to minimize the risk of electr...

Страница 28: ...R DAMAGES ARE CLAIMED THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT 9 Return Policy Except as otherwise provided TI does not offer any refunds returns or exchanges Furthe...

Страница 29: ...change without notice TI grants you permission to use these resources only for development of an application that uses the TI products described in the resource Other reproduction and display of thes...

Отзывы: