3. On JMP3-6, JMP9, JMP10, JMP15, and JMP16 move shuts from current position and install across pins 7-8.
4. Enable all devices by pulling their PD pins to GND. This is accomplished by placing a shunt on JMP8 across
pins 2-3.
5. Connect
Adapter to P4 (Note that the USB2ANY Adapter is not supplied with the
DS160PR412-421EVM). Install shunt on JMP17 across pins 1-2.
6. Install
Version 3.0.0.15 application and the DS160PR412-421 profile.
7. Plug the EVM into a PCIe x16 server motherboard slot. Ensure the motherboard is powered down before
installing the EVM or configured for hot-plug operation.
8. Install a compatible PCIe endpoint card into the straddle connector of the EVM.
9. Power-up the motherboard.
10.Start the SigCon Architect application.
11.Select the DS160PR412-421 Configuration Page and select the
Apply
box to enable the device profile. If
necessary, edit device addresses in the Edit Device Addresses box.
12.In the DS160PR412-421 High Level Page, select Block Diagram as shown in
.
13.Select desired EQ Settings and Driver VOD.
14.Select the devices to which you want to apply the selected settings and click the
Apply to All Channels
button.
Figure 2-1. SigCon Architect DS160PR412-421 High Level Page
Description
SNLU288 – DECEMBER 2020
DS160PR412-421EVM Evaluation Module
11
Copyright © 2020 Texas Instruments Incorporated