eQEP counter
PCEVNT
PCSOUT (active HIGH)
PCSOUT (active LOW)
PCSPW
eQEP Edge Capture Unit
835
SPRUH22I – April 2012 – Revised November 2019
Copyright © 2012–2019, Texas Instruments Incorporated
C28 Enhanced QEP (eQEP) Module
Figure 9-13. eQEP Position-compare Event Generation Points
The pulse stretcher logic in the position-compare unit generates a programmable position-compare sync
pulse output on the position-compare match. In the event of a new position-compare match while a
previous position-compare pulse is still active, then the pulse stretcher generates a pulse of specified
duration from the new position-compare event as shown in
Figure 9-14. eQEP Position-compare Sync Output Pulse Stretcher
9.5
eQEP Edge Capture Unit
The eQEP peripheral includes an integrated edge capture unit to measure the elapsed time between the
unit position events as shown in
. This feature is typically used for low speed measurement
using the following equation:
(3)
where,