Part List

3.3

Schemtic Drawing

Physical Description

Table 1

lists the parts used in constructing the EVM.

Table 1. TRF2436EVM PARTS LIST

QTY

Ref

Value

Part Number

Note

1

C1

470pF

GRM033R71C471KD

1

C2

10pF

GRM1555C1H100JZ

1

C3

5600pF

C0402C562K3RACT

7

C4 C6 C11 C15 C17 C24

0.01

µ

F

GRM155R71E103KA

C33

12

C5 C9 C12–C14 C16 C19

100pF

GRM1555C1H101JD

C20 C22 C25 C26 C31

3

C7 C8 C18

10

µ

F

ECJ-4YB1A106K

3

C10 C23 C29

1000pF

GRM155R71H102KA

2

C21 C32

1.2pF

04025A1R2BAT2A

1

C28

0.1

µ

F

ECJ-0EB1A104K

2

FL1 FL2

Filter, 2400–2484MHz

DFCB22G44LBJAA

DNI

2

FL3 FL4

Filter, 5597.5MHz

DFCB35G59LAHAA

DNI

1

FL5

Filter Block, DC power

BNX002-01

9

J1–J9

MXB SMA

142-0701-841

5

J10–J14

PA_A SEL

54201-S08-3

4

L1 R3 R4 R31

DNI

3

L2 L3 L7

27

at 100MHz

EXC-ML16A270U

4

L6 L8 L10 L12

120

at 100MHz

BLM15AG102SN1D

2

L9 L11

33nH

LQW15AN33NJ00D

1

P1

+3.3V_IN

ST-351A

1

P2

PSG

ST-351B

2

Q1 Q3

IRLML6401

IRLML6401

2

Q2 Q4

MMST2222A

MMST2222A-7

8

R1 R2 R6 R7 R35–R38

TRACE GAP, NO PART

DNI

1

R5

634

ERJ-2RKF6340X

9

R8–R13 R15 R32 R33

10K

ERJ-2GEJ103X

7

R16–R18 R24 R25 R28

1K

ERJ-2GEJ102X

R29

4

R20–R23

200

ERJ-2RKF2000X

1

R26

750

ERJ-2GEJ751X

1

R27

2K POT

3214W-1-202E

1

R30

5.1K

ERJ-2GEJ512X

1

T1

ADT4-1T

ADT4-1T

6

TP1–TP6

T POINT R

5015

1

U1

TRF2436

TRF2436

2

U2 U3

MMDT3906

MMDT3906-7

1

U4

MMDT3904

MMDT3904-7

The schematic drawing for the TRF2436EVM appears on the following page.

6

TRF2436EVM

SLWU038 – August 2006

Submit Documentation Feedback

Содержание Chipset TRF2436EVM

Страница 1: ...ply conditions Use this document with the EVM schematic diagram supplied Using the TRF2436EVM you can rapidly evaluate the TRF2436 with a minimum of manual setup Use the following equipment when evaluating the TRF2436EVM 3 3 V power supply 800 mA Signal generator Agilent ESG Series with baseband I Q modulation option for modulated testing or equivalent Spectrum analyzer Agilent PSA Series with pha...

Страница 2: ...t pins are brought out directly to SMA connectors on the EVM Filtering may be incorporated by Connecting an external filter to RFANTA J6 for filtering after the PA in TX mode or before the LNA in RX mode Connecting an external filter between the MFA J8 and RFA J9 jacks for filtering between the mixer and PA LNA stages 1 Connect 3 3 V to P1 and ground to P2 but do not turn on 2 Connect differential...

Страница 3: ...et to a desired RF frequency and typical power level of 20 dBm c Connect a spectrum analyzer to the IF J7 output d Turn on the 3 3 V power supply 90 mA e Observe the IF output on a spectrum analyzer 374 MHz 5 For LNA stage measurement a Terminate IF J7 and MFA J8 into 50 Ω b Connect an RF source to RFANTA J6 Set to a desired frequency and typical power level of 40 dBm c Connect a spectrum analyzer...

Страница 4: ...ucted on a 4 layer 3 6 inch 3 6 inch 0 042 inch thick PCB using Polycad 370 Turbo HR material Figure 1 through Figure 4 show the PCB layout for the EVM Figure 1 Top Layer 1 Figure 2 Ground Plane Layer 2 4 TRF2436EVM SLWU038 August 2006 Submit Documentation Feedback ...

Страница 5: ...www ti com Physical Description Figure 3 Power Plane Layer 3 Figure 4 Bottom Layer 4 SLWU038 August 2006 TRF2436EVM 5 Submit Documentation Feedback ...

Страница 6: ...Block DC power BNX002 01 9 J1 J9 MXB SMA 142 0701 841 5 J10 J14 PA_A SEL 54201 S08 3 4 L1 R3 R4 R31 DNI 3 L2 L3 L7 27Ω at 100MHz EXC ML16A270U 4 L6 L8 L10 L12 120Ω at 100MHz BLM15AG102SN1D 2 L9 L11 33nH LQW15AN33NJ00D 1 P1 3 3V_IN ST 351A 1 P2 PSG ST 351B 2 Q1 Q3 IRLML6401 IRLML6401 2 Q2 Q4 MMST2222A MMST2222A 7 8 R1 R2 R6 R7 R35 R38 TRACE GAP NO PART DNI 1 R5 634 ERJ 2RKF6340X 9 R8 R13 R15 R32 R3...

Страница 7: ...9 L LOA 10 V IF 11 V IFP 12 V IFN 13 RFA 14 V PA1A 15 V GEN 16 V PA2A 17 PABCA 18 V PA3A 19 BCOUT 20 BYPIN 21 BYPOUT 22 GND1 23 GND2 24 RFANTA 25 V LNABA 26 RFANTB 27 DETN 28 DETP 29 V PA3B 30 V PA2B 31 BCIN 32 PABCB 33 V PA1B 34 RSVD1 35 RFB 36 RXDGC 37 TR 38 LOADJB 39 TXGADJB 40 BACK 41 R37 TRACE GAP NO PART R37 TRACE GAP NO PART 1 2 TP2 TP2 1 TP1 TP1 1 C15 01uF C15 01uF 1 2 R2 TRACE GAP NO PART...

Страница 8: ...00MHz L7 27 OHM 100MHz R33 10K R33 10K 1 2 C9 100pF C9 100pF 1 2 C22 100pF C22 100pF 1 2 L11 33nH L11 33nH C11 01uF C11 01uF 1 2 C13 100pF C13 100pF 1 2 C17 01uF C17 01uF 1 2 R9 10K R9 10K R30 5 1K R30 5 1K C7 10uF C7 10uF 1 2 C6 01uF C6 01uF 1 2 L8 120 ohm 100MHz L8 120 ohm 100MHz L6 120 ohm 100MHz L6 120 ohm 100MHz R32 10K R32 10K 1 2 C23 1000pF C23 1000pF 1 2 L3 27 OHM 100MHz L3 27 OHM 100MHz F...

Страница 9: ...et of TRF2436EVM SCH A TRF2436 Evaluation Module B 3 3 Thursday April 13 2006 TP6 TP6 R17 1K R17 1K R16 1K R16 1K R18 1K R18 1K U3 MMDT3906 U3 MMDT3906 C2 B1 E1 E2 B2 C1 R29 1K R29 1K R24 1K R24 1K TP5 TP5 R22 200 R22 200 J12 ABSEL J12 ABSEL 1 2 3 R21 200 R21 200 C33 01uF C33 01uF 1 2 R20 200 R20 200 R23 200 R23 200 U2 MMDT3906 U2 MMDT3906 C2 B1 E1 E2 B2 C1 R28 1K R28 1K J13 TR J13 TR 1 2 3 R25 1K...

Страница 10: ...oduct This notice contains important safety information about temperatures and voltages For additional information on TI s environmental and or safety programs please contact the TI application engineer or visit www ti com esh No license is granted under any patent right or other intellectual property right of TI covering or relating to any machine process or combination in which such TI products ...

Страница 11: ...siness practice TI is not responsible or liable for any such statements TI products are not authorized for use in safety critical applications such as life support where a failure of the TI product would reasonably be expected to cause severe personal injury or death unless officers of the parties have executed an agreement specifically governing such use Buyers represent that they have all necess...

Отзывы: