Table 9-11. Fault and Status Condition Responses (continued)
FAULT or STATUS
ACTIONS
CHARGER
BEHAVIOR
SYS BEHAVIOR
LS/LDO
BEHAVIOR
TS BEHAVIOR
TS_FAULT COLD
or HOT
Update TS_FAULT to COLD
OR HOT, Update STAT to fault,
interrupt on INT
Disabled
Enabled (if enabled) Enabled (if enabled)
Enabled
TS_FAULT COOL
Update TS_FAULT to COOL,
Update STAT to fault, interrupt
on INT
Reduce ICHG to ½ Enabled (if enabled) Enabled (if enabled)
Enabled
TS_FAULT WARM
Update TS_FAULT to WARM,
Update STAT to fault, interrupt
on INT
Reduce VBATREG
by 140 mV
Enabled (if enabled) Enabled (if enabled)
Enabled
Charge Done
Update STAT to Charge Done,
interrupt on INT
Disabled, monitor
for VBAT falling
below VRCHG
Enabled (if enabled) Enabled (if enabled)
Enabled
READY STATE
After Reset, all default OTP settings
are used in this state.
CHARGING
The system charges the battery using
the programmed register settings,
default OTP settings, or the externally
programmed settings. Safety timers
are active in this state, unless disabled
in OTP or register settings.
FAULT
A failure occurred. The fault event
must be cleared before going to the
previous state.
DONE
The termination requirements have
been met. VBAT is monitored and
Charging resumes when conditions
are met.
RESET
y
VIN_OV
y
VIN_UV
y
OVER_TEMP
y
BAT_SHORT
y
BAT_OVP
y
CHARGING DONE|
TE
!FAULT|
!/CE & DONE
!FAULT|
/CE
y
VBAT
;
!TE
y
BAT_OVP
y
VIN_OV
y
TS_FAULT (HOT OR COLD)
/CE
!/CE
!FAULT|
!/CE
y
TIMER
y
VIN_OV
y
OVER_TEMP
y
TS_FAULT (HOT OR COLD)
Comments about naming convention
:
^
/
^
}Œ
^
HZ_
DK
^
-> Register name: event caused by user / configuration
^
!
^
-> Not
^
y
^
-> Event caused by external influence
^
Event|
condition
^
-> describes the event with a specific condition
/CE
HIGH_Z
Lowest quiescent current state. SYS
is powered by BAT, MR input is active,
and the LSCTRL input is active.
y
VBAT>VBAT_UVLO
y
VIN<VBAT+VSLP
y
CD
9
HZ_MODE
ACTIVE BATTERY
The device is powered from BAT, all
outputs and interfaces are active.
y
CD
;
|
VIN>VUVLO
y
CD
;
|
VIN<VUVLO
HZ_MODE
y
CD
9
y
VBAT>VBAT_UVLO
y
VIN<VBAT+VSLP
y
VIN>VUVLO
y
VIN>VBAT+VSLP
Figure 9-5. State Diagram
SLUSDA7A – APRIL 2018 – REVISED JANUARY 2021
Copyright © 2021 Texas Instruments Incorporated
31