Test Summary
•
Set
Pre-Charge Current Limit
to 256 mA
•
Un-Check
Enable Termination
(see
)
Figure 5. Main Window with Enable Termination Unchecked
•
Click the
Read
button three times, one second apart
Observe
→
Everything normal at
FAULT
box
Observe
→
D1 (STAT) is on
Enable Load #1 from
. Measure the system and battery voltage.
Measure
→
V(J3(SYS), J3(GND)) = 3.5 V ±300 mV
Measure
→
V(J5(BAT), J5(GND)) = 2.5 V ±200 mV
Increase the Load #1 voltage to 3.7 V.
Measure
→
V(J3(SYS), J3(GND)) = 3.75 V ±200 mV
Measure
→
IBAT = 500 mA ±200 mA
Measure
→
V(J5(BAT), J5(GND)) = 3.75 V ±200 mV
In the Software, Select Fast Charge Current, “ICHG” to 1024 mA.
Measure
→
Iin = 500 mA ±200 mA
2.4.2
Verify the device ID and JEITA shown in the software matches the following table:
Assy Number
EVM Part Number
Device ID
JEITA
PWR549-001
bq24295EVM-549
bq24295
Disabled
7
SLUUAO5B – August 2013 – Revised April 2014
bq24295EVM-549 (PWR549) User’s Guide
Copyright © 2013–2014, Texas Instruments Incorporated