Status Screen
8-6
To read or write a location:
-
Enter the address location of the register in the Address box. The register
and address can be selected from the pulldown menu.
-
Enter the data to be written if applicable.
-
Depress the Read or Write button.
The Send Break button sends a communication timing reset signal to the
bq2014H and should be depressed each time a bq2014H-based batter is con-
nected to the EV2200.
The program can continuously read a single address by using the dwell fea-
ture. To use the dwell feature:
-
Enter the address to read in the Dwell Address box, which can be selected
with the pulldown menu.
-
Set the dwell frequency in the Dwell Frequency box.
-
Click the Dwell button in the Dwell Contents box.
The contents of the register will start to scroll at the selected frequency.
8.6
Data Logging
The bq2014H registers can be logged by using the data log function. To log
the data and create a log file:
-
Select File|Start Data Log from the pulldown menu.
-
Enter a data log file name
-
Press OK
-
Set the data log interval
-
Press Close
-
To stop the data logging select File|Close Data Log from the pulldown
menu.
The file can be imported into a text editor, spreadsheet, or word processor pro-
gram.