1.3 Recommended Operating Conditions
Table 1-4. Recommended Operating Conditions
Description
MIN
TYP
MAX
Unit
V(VINx) at J1 or J2
Power supply voltage to the external blocking FETs
which allow power to VBUS pin
6
24
V
I(INx) into J1 or J2
Power supply current, which can be limited by charger's
input current limit feature (IINDPM)
0.01
3.3
A
V(BATTERY) voltage at J5 Battery voltage supported for pre charge
2.2
3.8(1S), 7.6(2S),
11.4(3S), 15.2V(4S)
18.8
V
I(BATTERY) out of/into J5
Battery charge current
0.01
2 (1S, 2S), 1(3S, 4S)
3
A
V(SYS) at J3
System voltage regulation range
3.2
19
V
I(SYS) out of J3
System load current
0
5
A