DCAN Registers
23.4.44 IF2DATB Register (offset = 134h) [reset = 0h]
IF2DATB is shown in
and described in
The data bytes of CAN messages are stored in the IF2 registers in the following order: (1) In a CAN data
frame, Data 0 is the first, and Data 7 is the last byte to be transmitted or received. (2) In CAN's serial bit
stream, the MSB of each byte will be transmitted first.
Figure 23-62. IF2DATB Register
31
30
29
28
27
26
25
24
Data_7
R/WP-0h
23
22
21
20
19
18
17
16
Data_6
R/WP-0h
15
14
13
12
11
10
9
8
Data_5
R/WP-0h
7
6
5
4
3
2
1
0
Data_4
R/WP-0h
LEGEND: R/W = Read/Write; R = Read only; W1toCl = Write 1 to clear bit; -n = value after reset
Table 23-57. IF2DATB Register Field Descriptions
Bit
Field
Type
Reset
Description
31-24
Data_7
R/WP
0h
Data 7.
23-16
Data_6
R/WP
0h
Data 6.
15-8
Data_5
R/WP
0h
Data 5.
7-0
Data_4
R/WP
0h
Data 4.
3976