6
Power Consumption
PLATEN SIZE
WATTS
AMPS
2” x 4”
600
2.5
3” x 5”
800
3.5
4” x 6”
880
3.7
5” x 6”
1680
7
3 ¼” x 5” Extended
Anvil
440
2
Connecting the Electrical Power Supply
Before connecting electrical power to the DES-30, push the DES-30’s toggle power switch down
to the “OFF” position. Plug the DES-30’s power cord into an appropriate power source, such as
a standard receptacle. The electrical power cord has a molded 15 amp plug.
Connecting Compressed Air
To connect the air supply to the DES-30, perform the following:
Remove the 1/8” male NPT pipe plug from the air line connector. The DES-30 includes
this plug during shipment to protect against contaminants entering the air system.
After removing the plug, connect the air supply to the DES-30’s 1/8” female NPT air line
connector.